Siemens

Siemens 6AV7611-0AF12-0BJ0 SIMATIC Panel PC 670 10" TFT Display

SKU 6AV7611-0AF12-0BJ0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7611-0AF12-0BJ0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7611-0AF12-0BJ0 is a SIMATIC Panel PC 670, an industrial panel personal computer designed for HMI and control applications. This unit features a 10" TFT Display and comes in a standard configuration including a Pentium III 500 MHz CPU, 64 MB RAM, and a 40 GB Hard Drive with a CD-ROM drive. It is pre-installed with Windows NT 4.0 English and includes a 115-230 V U.S. mains cable for power connection, making it suitable for various industrial environments requiring a robust computing platform.

Features

  • 10" TFT Display for clear visualization
  • Integrated Pentium III 500 MHz CPU
  • 64 MB RAM for system operation
  • 40 GB Hard Drive and CD-ROM for storage and media access
  • Pre-installed with Windows NT 4.0 English operating system
  • Designed for 115-230 V power supply (U.S. Mains Cable included)

Applications

The SIMATIC Panel PC 670 is typically deployed in industrial settings for:

  • Human-Machine Interface (HMI) applications
  • Process visualization and control
  • Data acquisition and logging
  • Machine operation and monitoring
  • Factory automation and manufacturing systems

Technical Specifications

Manufacturer Siemens
Series SIMATIC Panel PC 670
Model Number 6AV7611-0AF12-0BJ0
Display Type TFT
Display Size 10 inches
CPU Pentium III 500 MHz
RAM 64 MB
Storage 40 GB HD + CD-ROM
Operating System Windows NT 4.0 English
Power Supply 115-230 V (U.S. Mains Cable included)
Product Phase Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Safety First: Ensure all power to the installation area is de-energized before beginning any work.
  2. Mounting: Securely mount the Panel PC into a suitable industrial enclosure or panel cutout, ensuring proper ventilation clearances are maintained.
  3. Power Connection: Connect the supplied U.S. mains cable to a grounded 115-230 V AC power source. Verify the power supply voltage matches the unit's requirements.
  4. Grounding: Ensure the Panel PC chassis is properly grounded to the industrial enclosure's protective earth to prevent electrical hazards and ensure EMC compliance.
  5. Peripheral Connections: Connect any necessary industrial peripherals (e.g., keyboards, mice, network cables) to the appropriate ports.
  6. Power On: After all connections are verified, re-energize the power supply and power on the Panel PC.
  7. Software Configuration: Configure the Windows NT 4.0 operating system and any application software as required for the specific industrial task.

FAQ

What operating system is pre-installed on the Panel PC?

The Siemens 6AV7611-0AF12-0BJ0 comes with Windows NT 4.0 English pre-installed.

What are the key hardware specifications of this Panel PC?

It features a 10-inch TFT display, a Pentium III 500 MHz CPU, 64 MB of RAM, and a 40 GB hard drive with a CD-ROM drive.

What power supply voltage does this unit require?

The Panel PC operates on a 115-230 V AC power supply, and a U.S. mains cable is included.

Is this product still actively manufactured by Siemens?

No, the Siemens 6AV7611-0AF12-0BJ0 SIMATIC Panel PC 670 is listed as an obsolete product phase.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...