Siemens

Siemens 6AV7612-0AA12-0BF0 SIMATIC Panel PC 670

SKU 6AV7612-0AA12-0BF0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AA12-0BF0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.0 x 25.0 x 25.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7612-0AA12-0BF0 is a SIMATIC Panel PC 670, an integrated operator panel designed for machine-level control and visualization tasks in industrial environments. This standard configuration model features a 12-inch TFT touch display, an Intel Pentium III 500 MHz CPU, 64 MB of RAM, and a 20 GB hard drive. It is pre-installed with the Windows 98 operating system (English) and includes a U.S. mains cable for operation on 115-230V AC power sources. As an obsolete product, it serves as a direct replacement for existing systems.

Features

  • 12-inch TFT color touch display for operator interaction.
  • Integrated Intel Pentium III 500 MHz processor.
  • Equipped with 64 MB of system RAM.
  • Includes a 20 GB hard drive for operating system and application storage.
  • Pre-loaded with Microsoft Windows 98 (English version).
  • Supplied with a U.S. mains power cable for 115-230V AC input.

Applications

  • Human-Machine Interface (HMI) for process and machine control.
  • Data acquisition and logging stations.
  • Supervisory control in manufacturing and assembly lines.
  • Direct replacement for legacy systems utilizing the PC 670 platform.

Technical Specifications

Category Specification
General
Manufacturer Siemens
Product Series SIMATIC Panel PC 670
Part Number 6AV7612-0AA12-0BF0
Product Lifecycle Obsolete
Hardware
Display Type 12 inch TFT Touch Display
Processor (CPU) Intel Pentium III, 500 MHz
Memory (RAM) 64 MB
Storage 20 GB Hard Drive (HD)
Software
Operating System Windows 98 (English)
Electrical
Power Supply 115-230 V AC (via included U.S. mains cable)
Logistics
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 35.0 x 25.0 x 25.0 cm
Shipping Weight 12.00 kg
Commodity Code 85371091
ECCN N

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present. Installation must be performed by qualified personnel only. Disconnect and lock out all power sources before installation or maintenance to prevent electric shock and equipment damage.
  1. 1 Verify the panel cutout dimensions match the unit's specifications. Ensure the mounting surface is clean, flat, and can support the weight of the device.
  2. 2 Ensure adequate ventilation clearance around the rear of the unit as specified by the manufacturer to prevent overheating. Do not block ventilation slots.
  3. 3 Insert the Panel PC into the cutout and secure it using all provided mounting clamps. Tighten the clamps evenly to ensure a proper seal against the panel.
  4. 4 Connect the protective earth (PE) or functional ground terminal to the main system ground using a low-impedance conductor of the appropriate gauge.
  5. 5 Connect the provided mains power cable to the unit and to a stable, correctly rated AC power source.
  6. 6 Connect all required peripheral devices, such as keyboards, mice, and network cables, to their respective ports.
  7. 7 After verifying all connections are secure, restore power to the unit and confirm that the operating system boots correctly.

FAQ

What operating system is installed on this Panel PC?

This unit, part number 6AV7612-0AA12-0BF0, comes pre-installed with the English version of Windows 98.

What are the core hardware specifications?

The device is equipped with an Intel Pentium III 500 MHz processor, 64 MB of RAM, and a 20 GB hard drive for storage.

What is the display size and type?

It features a 12-inch TFT display with an integrated touch screen for operator input.

What are the power requirements?

This Panel PC operates on a 115-230V AC power source and is supplied with a U.S. mains power cable.

Is this product a current or obsolete model?

The Siemens SIMATIC Panel PC 670 is an obsolete product, primarily available as a spare part for maintaining existing industrial systems.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.