Siemens

Siemens 6AV7612-0AA20-0AF0 SIMATIC Panel PC 670 Panel PC

SKU 6AV7612-0AA20-0AF0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AA20-0AF0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 45 cm x 35 cm x 20 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7612-0AA20-0AF0 is a SIMATIC Panel PC 670, an integrated human-machine interface (HMI) designed for industrial control and visualization tasks. This standard configuration unit features a 12-inch TFT touch display, a Celeron 300 MHz CPU, and operates on a 24 VDC power supply. It is equipped with 128 MB of RAM and a 20 GB hard drive, pre-installed with the Windows 98 English operating system. Note that this product is considered obsolete under the manufacturer's Product Lifecycle Management (PLM) phase.

Features

  • 12-inch TFT color touch display for operator interaction.
  • Powered by a Celeron 300 MHz processor.
  • Includes 128 MB of system RAM.
  • Provides 20 GB of hard drive storage capacity.
  • Standard 24 VDC power input for industrial environments.
  • Comes with Windows 98 (English) operating system pre-installed.
  • Designed for panel mounting in industrial enclosures.

Applications

  • Process visualization and control
  • Machine-level data acquisition and logging
  • Supervisory Control and Data Acquisition (SCADA) clients
  • Factory automation HMI stations
  • Legacy system integration and maintenance

Technical Specifications

Specification Value
Manufacturer Siemens
Part Number 6AV7612-0AA20-0AF0
Product Series SIMATIC Panel PC 670
Product Type Panel PC
Display 12 inch TFT Touch Display
Processor (CPU) Celeron 300 MHz
Memory (RAM) 128 MB
Storage 20 GB Hard Drive (HD)
Power Supply 24 V DC
Operating System Windows 98 (English)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimated)
Package Dimensions (Calculated) 45 cm x 35 cm x 20 cm

Installation Guidelines

CRITICAL WARNING: Electrical hazard. Installation must be performed by qualified personnel only. Disconnect and lock out all power sources before accessing the enclosure. Failure to comply can result in severe injury or death.
  1. 1
    Prepare Panel Cutout: Ensure the mounting panel is clean, flat, and rigid. Create a cutout according to the device's mechanical drawings to ensure a proper fit and environmental seal. Deburr all sharp edges.
  2. 2
    Mount the Unit: Insert the Panel PC into the cutout from the front of the panel. Secure it from the rear using the provided mounting clamps. Tighten the clamps evenly and sequentially to the specified torque to avoid deforming the bezel and to maintain the IP rating.
  3. 3
    Connect Protective Earth (PE): Connect a low-impedance protective earth conductor to the designated PE terminal on the chassis. This is critical for personnel safety and electromagnetic compatibility (EMC).
  4. 4
    Connect Power Supply: Connect the 24 VDC power supply to the designated power input terminals. Verify correct polarity (+/-) before energizing. Use appropriately sized conductors and ensure the power source is stable and filtered.
  5. 5
    Connect Peripherals: Connect any required communication cables (e.g., Ethernet, serial) and I/O devices. Ensure all cable shields are properly terminated to the chassis ground to minimize noise interference. Power on the system and verify operation.

FAQ

What is the operating system on the 6AV7612-0AA20-0AF0?

This Panel PC comes pre-installed with the Windows 98 English operating system.

What is the required input voltage for this device?

The unit requires a 24 V DC power supply, which is standard for industrial control panels.

Is this Panel PC a current product?

No, the 6AV7612-0AA20-0AF0 is classified as an obsolete product according to Siemens' Product Lifecycle Management. It is suitable for maintenance, repair, and replacement of existing systems.

What are the key hardware specifications?

This model is configured with a Celeron 300 MHz CPU, 128 MB of RAM, and a 20 GB hard drive.

What is the display size and type?

It features a 12-inch TFT display with touch screen functionality for operator input.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.