Siemens

Siemens 6AV7612-0AA22-0AF0 SIMATIC Panel PC 670

SKU 6AV7612-0AA22-0AF0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AA22-0AF0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: Corrections Applied: none

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7612-0AA22-0AF0 is a SIMATIC Panel PC 670, an industrial panel personal computer designed for human-machine interface (HMI) and control applications. This unit features a 12" TFT Touch Display, providing an interactive interface for operators. It comes in a standard configuration with a 20 GB Hard Disk Drive, 128 MB RAM, and is powered by a Pentium III 500 MHz CPU. The panel PC operates on a 24 V DC power supply and is pre-installed with Windows 98 English, making it suitable for integration into existing industrial automation systems requiring this specific configuration.

Features

  • 12" TFT Touch Display
  • Pentium III 500 MHz CPU
  • 128 MB RAM
  • 20 GB Hard Disk Drive
  • 24 V DC Power Supply
  • Pre-installed with Windows 98 English

Applications

The Siemens SIMATIC Panel PC 670 is typically deployed in various industrial environments for:
  • Human-Machine Interface (HMI) for process control.
  • Data visualization and operational monitoring.
  • Machine control and automation systems.
  • Integration into existing SIMATIC automation architectures.
  • Industrial workstations requiring a robust, integrated PC solution.

Technical Specifications

Attribute Specification
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Type of Product PC panels
Display 12" TFT Touch Display
CPU Pentium III 500 MHz
RAM 128 MB
Hard Disk Drive 20 GB
Power Supply 24 V DC
Operating System Windows 98 English
Product Phase Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Safety First: Ensure all power to the installation area is de-energized before beginning any work. Verify with appropriate lockout/tagout procedures.
  2. Mounting: Mount the Panel PC securely into a control cabinet or panel cutout, ensuring adequate ventilation clearances as specified by the original equipment manufacturer.
  3. Power Connection: Connect the 24 V DC power supply to the designated terminals, observing correct polarity. Ensure the power source is stable and within the specified voltage range.
  4. Grounding: Establish a proper protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any necessary peripherals such as keyboards, mice, or network cables to the appropriate ports.
  6. Cable Management: Route all cables neatly and securely, separating power and signal cables where possible to prevent interference.
  7. Power Up: Once all connections are verified, re-energize the power supply and observe the Panel PC's startup sequence.

FAQ

What is the display type and size of the 6AV7612-0AA22-0AF0?

The Panel PC features a 12-inch TFT Touch Display.

What are the main hardware specifications of this Panel PC?

It is equipped with a Pentium III 500 MHz CPU, 128 MB RAM, and a 20 GB Hard Disk Drive.

What operating system is pre-installed on the 6AV7612-0AA22-0AF0?

The unit comes with Windows 98 English pre-installed.

What is the required power supply for the Siemens SIMATIC Panel PC 670?

The Panel PC operates on a 24 V DC power supply.

What is the product lifecycle status of this model?

The Siemens 6AV7612-0AA22-0AF0 SIMATIC Panel PC 670 is classified as obsolete.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Selecting and Troubleshooting DIN Valve Connectors

A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...