Siemens

Siemens 6AV7612-0AA30-0BE0 SIMATIC Panel PC 670

SKU 6AV7612-0AA30-0BE0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AA30-0BE0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 40 x 30 x 15 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is the Siemens 6AV7612-0AA30-0BE0, a SIMATIC Panel PC 670 designed for industrial automation and visualization applications. This unit integrates a computer and operator interface into a single device, featuring a 12-inch TFT touch display for direct machine control and monitoring. The standard configuration includes a Celeron 300 MHz CPU, 256 MB of RAM, and a 20 GB hard drive. It is engineered to operate on a 115-230V AC power supply and is supplied with a U.S. mains cable. This specific model comes with a pre-installed German language version of the Windows 98 operating system.

Features

  • 12-inch TFT color touch display
  • Integrated Celeron 300 MHz processor
  • 256 MB of installed RAM
  • 20 GB internal hard drive storage
  • Wide input voltage range of 115-230V AC
  • Pre-installed with Windows 98 (German language)

Applications

  • Machine-level data acquisition and control
  • Process visualization and HMI tasks
  • Factory automation and manufacturing execution systems (MES)
  • Industrial control panel integration

Technical Specifications

Specification Value
Brand Siemens
Model Number 6AV7612-0AA30-0BE0
Product Series SIMATIC Panel PC 670
Product Type Panel PC
Display 12-inch TFT Touch Display
Processor (CPU) Celeron 300 MHz
Memory (RAM) 256 MB
Storage 20 GB Hard Drive (HD)
Power Supply 115-230V AC
Operating System Windows 98 (German)
Product Lifecycle Phase Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N (Not subject to export control regulations)
Country of Origin Germany (Estimate)
Manufacturer Siemens AG
Package Dimensions (Calculated) 40 x 30 x 15 cm

Installation Guidelines

CRITICAL WARNING: Risk of electric shock. Installation must be performed by qualified personnel only. Ensure the main control cabinet is de-energized and locked-out/tagged-out (LOTO) before commencing any installation or maintenance work. Failure to comply can result in severe injury or death.
  1.  1 Verify the enclosure or panel has a cutout that matches the Panel PC's required mounting dimensions. Ensure the mounting surface is clean, flat, and free of debris.
  2.  2 Insert the Panel PC into the cutout from the front of the enclosure. Secure the unit from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal against the panel gasket.
  3.  3 Connect a protective earth (PE) conductor to the designated grounding terminal on the PC chassis. This connection is critical for safety and noise immunity.
  4.  4 Connect the 115-230V AC power supply using the provided U.S. mains cable to the power input connector. Ensure the source voltage matches the device rating.
  5.  5 Connect all necessary communication cables (e.g., Ethernet, serial) and any peripheral devices.
  6.  6 After verifying all connections are secure, remove the LOTO device and re-energize the main cabinet. Power on the Panel PC and confirm proper boot-up and operation.

FAQ

What operating system is installed on the 6AV7612-0AA30-0BE0?

This Panel PC comes pre-installed with a German language version of Windows 98.

What is the required input voltage for this device?

The unit is designed for a power supply of 115-230V AC.

Does this Panel PC include a power cable?

Yes, the product is supplied with a U.S. mains power cable.

What are the core hardware specifications?

It features a 12-inch TFT touch display, a Celeron 300 MHz CPU, 256 MB of RAM, and a 20 GB hard drive.

Is this a current product from Siemens?

No, the 6AV7612-0AA30-0BE0 is classified as an obsolete product, making it suitable as a spare part for existing systems.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.