Description

The Siemens 6AV7612-0AB10-0CF0 is a SIMATIC Panel PC 670 featuring a 12-inch TFT touch display. This industrial panel PC comes with a standard configuration including a 20 GB hard drive, a CD-ROM drive, 64 MB of RAM, and is powered by a Celeron 300 MHz CPU. Designed for industrial human-machine interface (HMI) applications, it operates on 115-230 V power and was originally supplied with Windows 98 English.

Features

  • 12-inch TFT Touch Display
  • Standard Configuration with 20 GB Hard Drive
  • Integrated CD-ROM Drive
  • 64 MB RAM
  • Celeron 300 MHz CPU
  • 115-230 V Power Input
  • Pre-installed Windows 98 English Operating System

Applications

The Siemens SIMATIC Panel PC 670 is suitable for a range of industrial automation and control applications, including:

  • Human-Machine Interface (HMI) for machine operation and monitoring
  • Process visualization in manufacturing and production lines
  • Data acquisition and local data processing
  • Control room and operator station integration
  • Industrial workstation for specialized software applications

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Product Type PC panels
Display Type 12" TFT Touch Display
Hard Drive Capacity 20 GB
Optical Drive CD-ROM
RAM 64 MB
CPU Celeron 300 MHz
Input Voltage 115-230 V
Operating System Windows 98 English
Product Phase Obsolete
Package Dimensions (Calculated) 0.10 x 0.10 x 0.10 cm
Shipping Weight 12.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. De-energize System: Ensure all power to the installation area and associated equipment is completely disconnected and locked out before beginning any work.
  2. Mounting: Securely mount the panel PC into a suitable industrial enclosure or control cabinet opening, ensuring proper sealing and ventilation as required by the environment.
  3. Power Connection: Connect the 115-230 V power supply cable to the designated power input terminals, observing correct polarity and grounding. Use appropriate cable glands to maintain enclosure integrity.
  4. Grounding: Establish a robust protective earth (PE) connection to the panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any required external devices such as keyboards, mice, or network cables to the appropriate ports. Ensure cables are routed to prevent strain and interference.
  6. Environmental Considerations: Verify that the operating environment (temperature, humidity, vibration) is within the specified limits for the panel PC to ensure reliable operation.
  7. Power-Up and Test: After all connections are secure and verified, restore power to the system and perform functional tests to confirm correct operation of the panel PC and its integrated display.

FAQ

What is the display type and size of this Panel PC?

The Siemens 6AV7612-0AB10-0CF0 features a 12-inch TFT touch display, suitable for interactive industrial applications.

What operating system is pre-installed on this unit?

This Panel PC was originally supplied with Windows 98 English.

What are the primary components of its standard configuration?

The standard configuration includes a 20 GB hard drive, a CD-ROM drive, 64 MB of RAM, and a Celeron 300 MHz CPU.

What voltage range does this Panel PC operate on?

The unit is designed to operate on a 115-230 V European mains cable.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.