Siemens

Siemens 6AV7612-0AE32-0BJ0 SIMATIC Panel PC 670

SKU 6AV7612-0AE32-0BJ0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AE32-0BJ0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: Corrections Applied: none

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7612-0AE32-0BJ0 is a SIMATIC Panel PC 670, an industrial personal computer designed for human-machine interface (HMI) and control applications. This unit features a 12-inch TFT Touch Display, a Pentium III 500 MHz CPU, 256 MB of RAM, and a 40 GB Hard Drive. It operates with a 115-230 V power supply and comes pre-installed with Windows NT 4.0 English, making it suitable for integration into existing industrial automation systems requiring a robust operator interface.

Features

  • 12-inch TFT Touch Display
  • Pentium III 500 MHz CPU
  • 256 MB RAM
  • 40 GB Hard Drive
  • Pre-installed Windows NT 4.0 English Operating System
  • 115-230 V Power Supply (U.S. Mains Cable included)

Applications

The SIMATIC Panel PC 670 is typically deployed in industrial environments for tasks such as:

  • Operator control and monitoring (HMI)
  • Data visualization and acquisition
  • Process control and automation
  • Machine operation and diagnostics
  • Integration into existing SIMATIC automation architectures

Technical Specifications

Brand Siemens
Manufacturer Siemens
Series SIMATIC Panel PC 670
Model 6AV7612-0AE32-0BJ0
Display Type 12-inch TFT Touch Display
CPU Pentium III 500 MHz
RAM 256 MB
Hard Drive 40 GB
Operating System Windows NT 4.0 English
Power Supply 115-230 V (U.S. Mains Cable)
Product Phase Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Power De-energization: Ensure all power to the installation site is disconnected and locked out before beginning any work.
  2. Mounting: Mount the Panel PC securely in a suitable control cabinet or panel cutout, ensuring adequate ventilation for heat dissipation.
  3. Grounding: Connect the protective earth (PE) terminal of the Panel PC to the cabinet's ground bus using a low-impedance connection. Proper grounding is crucial for safety and electromagnetic compatibility.
  4. Power Connection: Connect the 115-230 V AC power supply using the provided U.S. mains cable or an appropriate industrial power connector, observing correct polarity and voltage ratings.
  5. Peripheral Connections: Connect any required peripherals such as keyboards, mice, or external storage devices to the available ports.
  6. Network Connections: If applicable, connect to the industrial network using appropriate shielded cables to minimize interference.
  7. Environmental Considerations: Ensure the operating environment meets the specified temperature, humidity, and vibration limits for industrial PC equipment.
  8. Power-Up: After all connections are verified, re-energize the power supply and observe the system startup.

FAQ

What operating system is pre-installed on the 6AV7612-0AE32-0BJ0?

The Siemens 6AV7612-0AE32-0BJ0 comes with Windows NT 4.0 English pre-installed.

What is the display size and type of this Panel PC?

It features a 12-inch TFT Touch Display.

What are the key hardware specifications of the 6AV7612-0AE32-0BJ0?

It includes a Pentium III 500 MHz CPU, 256 MB of RAM, and a 40 GB Hard Drive.

What power supply voltage does this Panel PC require?

The unit operates on a 115-230 V AC power supply.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...