Siemens

Siemens 6AV7612-0AF12-0BG0 SIMATIC Panel PC 670

SKU 6AV7612-0AF12-0BG0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7612-0AF12-0BG0

  • Country of origin:Germany

  • Product Type: PC Panel

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: Corrections Applied: none

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7612-0AF12-0BG0 is a SIMATIC Panel PC 670 featuring a 12-inch TFT touch display. This industrial panel PC comes with a standard configuration including a 40 GB hard drive, a CD-ROM drive, and 64 MB of RAM. It is powered by a Pentium III 500 MHz CPU and operates on 115-230 V power, supplied with a U.S. mains cable. The unit is pre-installed with Windows 2000 Multi-Language, supporting English, German, French, Italian, and Spanish.

Features

  • 12-inch TFT Touch Display
  • Pentium III 500 MHz CPU
  • 64 MB RAM
  • 40 GB Hard Drive
  • Integrated CD-ROM Drive
  • Pre-installed Windows 2000 Multi-Language (EN, GER, FR, IT, SP)
  • 115-230 V AC Power Input (U.S. Mains Cable included)

Applications

The SIMATIC Panel PC 670 is suitable for various industrial applications requiring human-machine interface (HMI), process visualization, data acquisition, and control tasks in manufacturing, automation, and process industries. Its robust design allows for deployment in demanding industrial environments.

Technical Specifications

Parameter Value
Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Type of Product PC panels
Product Phase Obsolete
Display Type 12" TFT Touch Display
CPU Pentium III 500 MHz
RAM 64 MB
Hard Drive 40 GB
Optical Drive CD-ROM
Operating System Windows 2000 Multi-Language (EN, GER, FR, IT, SP)
Power Input 115-230 V (U.S. Mains Cable included)
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. De-energize System: Before commencing any installation or maintenance, ensure that all power sources to the system and the panel PC are completely de-energized and locked out according to safety procedures.
  2. Mounting: Securely mount the panel PC in a stable location, ensuring adequate ventilation and protection from excessive vibration, dust, and moisture.
  3. Power Connection: Connect the provided U.S. mains cable to the panel PC's power input and then to a compatible 115-230 V AC power supply. Verify correct voltage and polarity.
  4. Grounding: Establish a proper earth ground connection for the panel PC to prevent electrical hazards and ensure stable operation, following local electrical codes.
  5. Peripheral Connections: Connect any required industrial peripherals, such as keyboards, mice, or communication cables, to the appropriate ports.
  6. Power Up: Once all connections are secure, re-energize the system and power on the panel PC.
  7. Software Configuration: Perform any necessary software configuration or driver installations as required for the specific application.

FAQ

What operating system is pre-installed on the 6AV7612-0AF12-0BG0?

The unit comes with Windows 2000 Multi-Language pre-installed, supporting English, German, French, Italian, and Spanish.

What are the display specifications of this Panel PC?

It features a 12-inch TFT touch display.

What are the power requirements for the SIMATIC Panel PC 670?

The Panel PC operates on 115-230 V AC power and includes a U.S. mains cable.

What is the CPU and memory configuration?

The unit is equipped with a Pentium III 500 MHz CPU and 64 MB of RAM.

Is the 6AV7612-0AF12-0BG0 still an active product?

According to the product phase information, this model is obsolete.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...