Siemens

Siemens 6AV7613-0AB22-0BE0 SIMATIC Panel PC 670

SKU 6AV7613-0AB22-0BE0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7613-0AB22-0BE0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.0 x 25.0 x 25.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a Siemens 6AV7613-0AB22-0BE0 SIMATIC Panel PC 670, an industrial computer designed for human-machine interface (HMI) and control applications. This standard configuration features a 12-inch TFT display, a Pentium III 500 MHz CPU, and is equipped with 128 MB of RAM. For storage, it includes a 20 GB hard drive and an integrated CD-ROM drive. The unit is powered by a 115-230V supply and comes with a U.S. mains cable. Please note, this model is part of an obsolete product line and is supplied with a German-language version of Windows 98.

Features

  • 12-inch TFT color display for process visualization
  • Pentium III processor operating at 500 MHz
  • 128 MB of system RAM
  • 20 GB internal hard drive for application and data storage
  • Integrated CD-ROM drive for software installation
  • Wide input voltage range of 115-230V AC

Applications

  • Machine-level HMI and process control
  • Data acquisition and logging systems
  • Supervisory control in manufacturing lines
  • Replacement for legacy PC-based control systems
  • Industrial automation and plant floor visualization

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Panel PC 670
Display 12-inch TFT
Processor (CPU) Pentium III, 500 MHz
Memory (RAM) 128 MB
Storage 20 GB Hard Drive (HD)
Optical Drive CD-ROM
Power Supply 115-230V AC (Supplied with U.S. Mains Cable)
Operating System Windows 98 (German Language)
Product Lifecycle Status Obsolete
Country of Origin Germany (Estimated)
Package Dimensions (Calculated) 35.0 x 25.0 x 25.0 cm
Shipping Weight 12.00 kg
Harmonized Tariff Code 85371091
ECCN N

Installation Guidelines

CRITICAL WARNING: Hazardous voltages are present. Installation must be performed by qualified personnel only. Failure to de-energize equipment and follow Lockout/Tagout (LOTO) procedures before installation can result in severe injury or death.
  1. 1 Ensure the control cabinet is de-energized and locked out. Verify the absence of voltage before proceeding.
  2. 2 Prepare the panel cutout according to the manufacturer's dimensional drawings for the PC 670 series. Ensure the mounting surface is clean, flat, and rigid.
  3. 3 Mount the Panel PC into the cutout and secure it using the provided mounting clamps. Tighten clamps evenly to the specified torque to ensure a proper seal and prevent bezel distortion.
  4. 4 Connect the protective earth (PE) conductor to the designated chassis ground terminal. A low-impedance ground connection is critical for safety and noise immunity.
  5. 5 Connect the 115-230V AC power supply using the provided mains cable. Ensure the source voltage matches the unit's requirements. Route power cables separately from signal and communication cables.
  6. 6 Connect all required communication and I/O cables. After installation is complete and the cabinet is closed, remove the lockout and re-energize the system for commissioning.

FAQ

What operating system is installed on the 6AV7613-0AB22-0BE0?

This unit is supplied with a German-language version of Windows 98.

What is the processor and speed of this Panel PC?

It is equipped with a Pentium III CPU operating at 500 MHz.

Does this Panel PC include a power cable?

Yes, the product is supplied with a U.S. mains cable compatible with a 115-230V AC power source.

What is the screen size and type?

The device features a 12-inch TFT display.

What is the product lifecycle status of this model?

The Siemens 6AV7613-0AB22-0BE0 is an obsolete product, typically sourced for legacy system maintenance and repair.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.