Description

The Siemens 6AV7613-0AB32-0CH0 is a SIMATIC Panel PC 670, designed for industrial human-machine interface (HMI) and control applications. This unit features a 12" TFT display, providing a clear visual interface for operators. It comes with a standard configuration including a 20 GB hard drive, a CD-ROM drive, and 256 MB of RAM. The Panel PC is powered by a Pentium III 500 MHz CPU and operates on a 115-230 V power supply, suitable for European mains. The pre-installed operating system is Windows NT 4.0 German, making it suitable for specific legacy industrial environments.

Features

  • 12" TFT Display
  • Pentium III 500 MHz CPU
  • 256 MB RAM
  • 20 GB Hard Drive
  • Integrated CD-ROM Drive
  • 115-230 V Power Supply
  • Pre-installed Windows NT 4.0 (German)

Applications

The Siemens SIMATIC Panel PC 670 is typically deployed in industrial settings requiring a robust and integrated computing platform for:

  • Process visualization and control
  • Machine operation and monitoring
  • Data acquisition and logging
  • Supervisory control and data acquisition (SCADA) systems
  • Manufacturing execution systems (MES) interfaces

Technical Specifications

Parameter Value
Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Type of Product PC panels
Display Type 12" TFT Display
Hard Drive Capacity 20 GB
Optical Drive CD-ROM
RAM 256 MB
CPU Pentium III 500 MHz
Power Supply 115-230 V
Operating System Windows NT 4.0 German
Product Phase Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Power De-energization: Before commencing any installation or maintenance, ensure that all power to the Panel PC and associated equipment is completely de-energized and locked out according to site safety procedures.
  2. Mounting: Securely mount the Panel PC into a suitable control cabinet or panel cutout. Ensure adequate space for ventilation and cable routing.
  3. Power Connection: Connect the 115-230 V mains cable to the designated power input terminals. Verify correct voltage and polarity before applying power.
  4. Grounding: Establish a proper protective earth (PE) connection to the Panel PC chassis. This is crucial for operational safety and electromagnetic compatibility.
  5. Peripheral Connections: Connect any required peripherals such as keyboards, mice, or external storage devices to the appropriate ports.
  6. Cable Routing: Route all cables to minimize electromagnetic interference (EMI) and mechanical stress. Separate power cables from signal cables where possible.
  7. Environmental Considerations: Ensure the installation environment meets the specified operating conditions for temperature, humidity, and vibration to ensure long-term reliability.

FAQ

What is the primary function of the Siemens 6AV7613-0AB32-0CH0?

The 6AV7613-0AB32-0CH0 is an industrial Panel PC designed for human-machine interface (HMI) and control applications in various industrial environments.

What operating system is pre-installed on this Panel PC?

This SIMATIC Panel PC 670 comes with Windows NT 4.0 German pre-installed, suitable for specific legacy system integrations.

What are the key hardware specifications of this unit?

It features a 12-inch TFT display, a Pentium III 500 MHz CPU, 256 MB of RAM, a 20 GB hard drive, and an integrated CD-ROM drive.

Is this product still actively manufactured by Siemens?

No, the 6AV7613-0AB32-0CH0 is listed as 'Obsolete' in its product lifecycle management phase.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.