Siemens

Siemens 6AV7613-0AB32-0CH0 SIMATIC Panel PC 670

SKU 6AV7613-0AB32-0CH0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7613-0AB32-0CH0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: Corrections Applied: none

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7613-0AB32-0CH0 is a SIMATIC Panel PC 670, designed for industrial human-machine interface (HMI) and control applications. This unit features a 12" TFT display, providing a clear visual interface for operators. It comes with a standard configuration including a 20 GB hard drive, a CD-ROM drive, and 256 MB of RAM. The Panel PC is powered by a Pentium III 500 MHz CPU and operates on a 115-230 V power supply, suitable for European mains. The pre-installed operating system is Windows NT 4.0 German, making it suitable for specific legacy industrial environments.

Features

  • 12" TFT Display
  • Pentium III 500 MHz CPU
  • 256 MB RAM
  • 20 GB Hard Drive
  • Integrated CD-ROM Drive
  • 115-230 V Power Supply
  • Pre-installed Windows NT 4.0 (German)

Applications

The Siemens SIMATIC Panel PC 670 is typically deployed in industrial settings requiring a robust and integrated computing platform for:

  • Process visualization and control
  • Machine operation and monitoring
  • Data acquisition and logging
  • Supervisory control and data acquisition (SCADA) systems
  • Manufacturing execution systems (MES) interfaces

Technical Specifications

Parameter Value
Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Type of Product PC panels
Display Type 12" TFT Display
Hard Drive Capacity 20 GB
Optical Drive CD-ROM
RAM 256 MB
CPU Pentium III 500 MHz
Power Supply 115-230 V
Operating System Windows NT 4.0 German
Product Phase Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Power De-energization: Before commencing any installation or maintenance, ensure that all power to the Panel PC and associated equipment is completely de-energized and locked out according to site safety procedures.
  2. Mounting: Securely mount the Panel PC into a suitable control cabinet or panel cutout. Ensure adequate space for ventilation and cable routing.
  3. Power Connection: Connect the 115-230 V mains cable to the designated power input terminals. Verify correct voltage and polarity before applying power.
  4. Grounding: Establish a proper protective earth (PE) connection to the Panel PC chassis. This is crucial for operational safety and electromagnetic compatibility.
  5. Peripheral Connections: Connect any required peripherals such as keyboards, mice, or external storage devices to the appropriate ports.
  6. Cable Routing: Route all cables to minimize electromagnetic interference (EMI) and mechanical stress. Separate power cables from signal cables where possible.
  7. Environmental Considerations: Ensure the installation environment meets the specified operating conditions for temperature, humidity, and vibration to ensure long-term reliability.

FAQ

What is the primary function of the Siemens 6AV7613-0AB32-0CH0?

The 6AV7613-0AB32-0CH0 is an industrial Panel PC designed for human-machine interface (HMI) and control applications in various industrial environments.

What operating system is pre-installed on this Panel PC?

This SIMATIC Panel PC 670 comes with Windows NT 4.0 German pre-installed, suitable for specific legacy system integrations.

What are the key hardware specifications of this unit?

It features a 12-inch TFT display, a Pentium III 500 MHz CPU, 256 MB of RAM, a 20 GB hard drive, and an integrated CD-ROM drive.

Is this product still actively manufactured by Siemens?

No, the 6AV7613-0AB32-0CH0 is listed as 'Obsolete' in its product lifecycle management phase.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...

Seal-In Logic or OTL/OTU? Choosing PLC Memory Safely

Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...