Description

This is a Siemens 6AV7613-0AE22-0BG0 SIMATIC Panel PC 670, an industrial-grade human-machine interface (HMI) designed for machine-level control and visualization tasks. The unit is equipped with a 12-inch TFT display and is part of the established SIMATIC PC670 series. As an obsolete product, it serves as a critical spare part for maintaining and extending the life of existing automation systems that rely on this specific hardware platform.

Features

  • Integrated 12-inch TFT color display
  • Robust construction for industrial environments
  • Part of the Siemens SIMATIC Panel PC family
  • Designed for panel mounting applications

Applications

  • Process visualization and control
  • Machine data acquisition and logging
  • Operator control stations in manufacturing
  • Supervisory Control and Data Acquisition (SCADA) nodes
  • Replacement unit for legacy automation systems

Technical Specifications

Specification Value
Brand Siemens
Product Series SIMATIC Panel PC 670
Product Type Panel PC
Display Type 12-inch TFT
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control (ECCN) N
Country of Origin Germany (Estimate)
Manufacturer Siemens
Package Dimensions (Calculated) 45 cm x 35 cm x 20 cm

Installation Guidelines

CRITICAL WARNING: Electrical Hazard. Installation must be performed by qualified personnel only. Ensure the control panel is completely de-energized and locked out (LOTO) before beginning any installation, wiring, or maintenance procedures. Failure to comply can result in severe injury or death.
  1. 1 Panel Cutout: Verify that the panel cutout dimensions precisely match the requirements for the PC 670 chassis. Ensure the mounting surface is flat, clean, and rigid enough to support the unit's weight and withstand operational vibration.
  2. 2 Mounting: Insert the Panel PC into the cutout from the front of the enclosure. Secure it from the rear using the provided mounting clamps. Tighten the clamps evenly in a cross-pattern to ensure a uniform seal against the panel gasket. Do not over-torque the clamps.
  3. 3 Protective Earth (PE) Connection: Connect the chassis to the control panel's protective earth busbar using a low-impedance conductor. This connection is critical for both electrical safety and noise immunity. Use a dedicated grounding stud on the PC chassis if available.
  4. 4 Power Supply Wiring: Connect the specified DC or AC power source to the unit's power input terminal. Ensure the voltage and polarity are correct. Use appropriately sized wiring and route power cables separately from communication and I/O cables to minimize electromagnetic interference.
  5. 5 Interface Connections: Connect all required communication cables (e.g., Ethernet, PROFIBUS, serial) and peripherals (e.g., keyboard, mouse). Ensure all connectors are fully seated and secured. Use shielded cables for all data communication lines and ensure shields are properly terminated.

FAQ

What is the lifecycle status of the 6AV7613-0AE22-0BG0?

The Siemens 6AV7613-0AE22-0BG0 is classified as an obsolete product. It is primarily available as a spare part for maintaining existing industrial automation systems.

What is the screen size of this SIMATIC Panel PC?

This model features a 12-inch TFT display for operator visualization and control.

Is this a complete, ready-to-install unit?

Yes, this is a complete Panel PC unit. However, it does not include operating system licenses, application software, or connection cables unless specified otherwise.

What is the primary application for this Panel PC?

It is designed for industrial HMI (Human-Machine Interface) applications, including process control, data acquisition, and machine-level visualization within a control cabinet or operator console.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.