Siemens

Siemens 6AV7613-0AF20-0CJ0 SIMATIC Panel PC 670

SKU 6AV7613-0AF20-0CJ0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7613-0AF20-0CJ0

  • Country of origin:Germany

  • Product Type: PC Panel

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.00 x 25.00 x 25.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7613-0AF20-0CJ0 is a SIMATIC Panel PC 670, featuring a 12-inch TFT display. This industrial panel PC is configured with a 40 GB hard drive, a CD-ROM drive, and 128 MByte of RAM. It is powered by a Celeron 300 MHz CPU and operates with a 115-230 V European mains cable. The unit comes pre-installed with Windows NT 4.0 English, making it suitable for human-machine interface (HMI) and control applications within industrial environments.

Features

  • 12-inch TFT Display
  • Standard Configuration: 40 GB Hard Drive + CD-ROM
  • 128 MByte RAM
  • Celeron 300 MHz CPU
  • 115-230 V European Mains Cable
  • Pre-installed Windows NT 4.0 English

Applications

The SIMATIC Panel PC 670 is typically deployed in industrial settings requiring robust HMI solutions, data visualization, and process control. Its design supports integration into manufacturing lines, automation systems, and monitoring stations where a dedicated industrial computer with a display is necessary for operator interaction and data management.

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range SIMATIC Panel PC
Subrange PC670
Product Type PC Panel
Display 12-inch TFT
Storage 40 GB HD + CD-ROM
RAM 128 MByte
CPU Celeron 300 MHz
Operating System Windows NT 4.0 English
Power Supply 115-230 V
Product Phase Obsolete
Package Dimensions (Calculated) 35.00 x 25.00 x 25.00 cm
Shipping Weight 12.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Safety First: Ensure all power to the installation area is de-energized and locked out before beginning any work.
  2. Mounting: Mount the Panel PC securely into a suitable panel cutout or enclosure, ensuring adequate clearance for ventilation and cable routing.
  3. Power Connection: Connect the 115-230 V mains cable to a stable and protected power source. Verify correct voltage and grounding.
  4. Grounding: Establish a proper protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any required industrial peripherals (e.g., keyboards, mice, network cables) to the appropriate ports.
  6. Environmental Considerations: Ensure the operating environment meets the specified temperature and humidity ranges for industrial PC equipment to prevent premature failure.
  7. Power On: After all connections are verified, re-energize the power supply and power on the Panel PC.

FAQ

What operating system is pre-installed on the 6AV7613-0AF20-0CJ0?

The Siemens 6AV7613-0AF20-0CJ0 comes with Windows NT 4.0 English pre-installed.

What is the display size of this Panel PC?

This SIMATIC Panel PC 670 features a 12-inch TFT display.

What are the power requirements for this unit?

The Panel PC operates with a 115-230 V European mains cable.

Is the 6AV7613-0AF20-0CJ0 still an active product?

No, the product phase for this model is listed as obsolete.

What is the primary application of the SIMATIC Panel PC 670?

It is primarily used for Human-Machine Interface (HMI), data visualization, and process control in industrial automation environments.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...