Description
The Siemens 6AV7613-0AF22-0AH0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This unit features a 12-inch TFT display and is powered by an Intel Pentium III 500 MHz processor. It is equipped with 128 MB of RAM, a 40 GB hard drive, and an integrated CD-ROM drive. The system operates on a 24 V DC power supply and comes pre-installed with the Windows NT 4.0 operating system in German. This model is designated as an obsolete product, making it suitable for maintaining or repairing legacy automation systems.
Features
- 12-inch TFT color display for process visualization.
- Intel Pentium III 500 MHz central processing unit.
- 128 MB of system RAM.
- 40 GB internal hard drive for data and application storage.
- Integrated CD-ROM drive for software installation and data transfer.
- Operates on a nominal 24 V DC industrial power source.
- Pre-loaded with Windows NT 4.0 (German language version).
Applications
- Machine control interfaces (HMI)
- Process visualization and monitoring
- Supervisory Control and Data Acquisition (SCADA) nodes
- Data logging and reporting stations
- Replacement unit for legacy manufacturing systems
Technical Specifications
| Specification |
Value |
| Manufacturer |
Siemens |
| Part Number |
6AV7613-0AF22-0AH0 |
| Product Series |
SIMATIC Panel PC 670 |
| Display |
12 inch TFT |
| Processor (CPU) |
Intel Pentium III 500 MHz |
| Memory (RAM) |
128 MB |
| Storage |
40 GB Hard Drive (HD) |
| Optical Drive |
CD-ROM |
| Power Supply Input |
24 V DC |
| Operating System |
Windows NT 4.0 (German) |
| Product Lifecycle Status |
Obsolete |
| Shipping Weight |
12.00 kg |
| Commodity Code |
85371091 |
| ECCN |
N |
| Country of Origin |
Germany (Estimate) |
| Package Dimensions (Calculated) |
0.10 x 0.10 x 0.10 cm (Placeholder) |
Installation Guidelines
CRITICAL WARNING: Hazardous voltages may be present. Installation must be performed by qualified personnel only. De-energize and lock out/tag out all power sources before accessing the control cabinet or attempting installation. Failure to comply can result in severe injury or death.
-
1
Prepare Mounting Location: Ensure the panel cutout dimensions match the PC 670's requirements. The mounting surface must be flat, clean, and capable of supporting the unit's weight (12.00 kg). Verify adequate clearance for ventilation and cable routing at the rear of the unit.
-
2
Install the Unit: Insert the Panel PC into the prepared cutout from the front. Secure it from the rear using the provided mounting clamps. Tighten the clamps evenly in a diagonal pattern to ensure a uniform seal against the panel gasket. Do not overtighten.
-
3
Connect Protective Earth (PE): Connect a low-impedance protective earth conductor to the designated PE terminal on the Panel PC chassis. This is a critical safety connection to protect against electric shock and improve noise immunity.
-
4
Connect Power Supply: Connect the 24 V DC power source to the power input terminals. Verify correct polarity (+/-) before connection. Use appropriately sized conductors and ensure the power supply is stable and filtered.
-
5
Connect Peripherals: Connect all required communication cables (e.g., Ethernet, PROFIBUS) and I/O devices. Ensure all connectors are fully seated and secured. Route cables to prevent strain and interference with other components.