Siemens

Siemens 6AV7614-0AA20-0BE0 SIMATIC Panel PC 670 Panel PC

SKU 6AV7614-0AA20-0BE0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7614-0AA20-0BE0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 48 cm x 40 cm x 15 cm (Estimated)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7614-0AA20-0BE0 is a SIMATIC Panel PC 670, an integrated human-machine interface (HMI) designed for industrial control and visualization applications. This unit features a 15-inch TFT touch display, an Intel Celeron 300 MHz processor, 128 MB of RAM, and a 20 GB hard drive. It is configured for a 115-230V AC power supply and includes a U.S. mains cable. This specific model comes pre-installed with a German language version of Windows 98 and is classified as an obsolete product, making it suitable for maintaining or replacing components in legacy automation systems.

Features

  • ■15-inch TFT color touch screen for operator control
  • ■Integrated Intel Celeron 300 MHz CPU
  • ■128 MB of installed RAM
  • ■20 GB hard disk drive for application and data storage
  • ■Supports 115-230V AC power input
  • ■Pre-installed with Windows 98 (German language version)

Applications

  • ■Machine-level control and monitoring
  • ■Process visualization and data acquisition
  • ■Factory automation systems
  • ■Replacement for failed units in existing legacy installations

Technical Specifications

Specification Value
Manufacturer Siemens
Part Number 6AV7614-0AA20-0BE0
Product Family SIMATIC Panel PC
Series PC 670
Display Type 15-inch TFT Touch Display
Processor Intel Celeron 300 MHz
Memory (RAM) 128 MB
Storage 20 GB Hard Drive (HD)
Input Voltage 115-230 V AC
Included Cable U.S. Mains Cable
Operating System Windows 98 (German)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimated)
Package Dimensions (Calculated) 48 cm x 40 cm x 15 cm (Estimated)

Installation Guidelines

CRITICAL WARNING: This is an obsolete electronic device. Installation must be performed by qualified personnel only. Failure to adhere to safety procedures can result in equipment damage, data loss, or severe personal injury. Always handle with appropriate Electrostatic Discharge (ESD) precautions.
  1. 1
    De-energize Equipment: Before installation, completely de-energize the control cabinet or mounting location. Apply Lockout/Tagout (LOTO) procedures to prevent accidental power-up.
  2. 2
    Verify Panel Cutout: Confirm that the panel cutout dimensions match the requirements for the PC 670 chassis. Ensure adequate clearance for ventilation and cable routing.
  3. 3
    Mount the Unit: Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal against the panel surface. Do not over-torque.
  4. 4
    Establish Ground Connection: Connect a protective earth (PE) or grounding wire to the designated grounding terminal on the Panel PC chassis. This is the first electrical connection to be made.
  5. 5
    Connect Power and I/O: Connect the 115-230V AC mains cable to the power input terminal. Connect all required communication cables (e.g., Ethernet, serial) and any other peripheral devices.
  6. 6
    Final System Check: After removing LOTO and re-energizing the cabinet, power on the Panel PC. Verify that the operating system boots correctly and that all communication links with other system components are established.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.