Siemens

Siemens 6AV7614-0AB32-0AF0 SIMATIC Panel PC 670 Panel PC

SKU 6AV7614-0AB32-0AF0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7614-0AB32-0AF0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 45 x 35 x 15 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7614-0AB32-0AF0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This specific configuration features a 15-inch TFT touch display and is powered by an Intel Pentium III 500 MHz processor. It is equipped with 256 MB of RAM, a 20 GB hard drive, and an integrated CD-ROM drive for software installation and data access. The unit operates on a standard 24 V DC industrial power supply and comes pre-installed with the Windows 98 operating system in English.

Features

  • 15-inch TFT color display with touch functionality
  • Intel Pentium III 500 MHz CPU
  • 256 MB of installed RAM
  • 20 GB internal hard drive for OS and application storage
  • Built-in CD-ROM optical drive
  • Standard 24 V DC power input requirement
  • Pre-loaded with Windows 98 (English) operating system

Applications

  • Legacy machine control and process visualization
  • Supervisory Control and Data Acquisition (SCADA) nodes
  • Industrial data logging and reporting stations
  • Factory floor operator interfaces
  • Maintenance and diagnostics for existing automated systems

Technical Specifications

Specification Value
Product Type Panel PC
Display 15-inch TFT Touch Display
Processor (CPU) Pentium III 500 MHz
Memory (RAM) 256 MB
Storage 20 GB Hard Drive (HD)
Optical Drive CD-ROM
Power Supply 24 V DC
Operating System Windows 98 (English)
Product Series SIMATIC Panel PC 670
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimate)
Manufacturer Siemens
Package Dimensions (Calculated) 45 x 35 x 15 cm

Installation Guidelines

CRITICAL WARNING: Electrical Hazard. Installation, wiring, and maintenance must be performed by qualified personnel only. Failure to de-energize the system before service can result in severe injury or death. Always follow local Lockout/Tagout (LOTO) procedures.
  1. 1
    Panel Preparation: Ensure the control cabinet or panel cutout dimensions match the unit's mounting requirements. The mounting surface must be flat, clean, and capable of supporting the device weight. Verify adequate clearance for ventilation and cable routing at the rear of the unit.
  2. 2
    Mounting: Secure the Panel PC into the cutout using the provided mounting clamps. Tighten clamps evenly to the manufacturer's recommended torque specification to ensure a proper seal and prevent chassis distortion. Do not overtighten.
  3. 3
    Grounding: Connect the chassis grounding terminal to the main protective earth (PE) busbar of the cabinet using a low-impedance conductor. A reliable ground connection is critical for operator safety and noise immunity.
  4. 4
    Power Connection: Connect a stable, correctly rated 24 V DC power source to the designated power input terminals. Ensure correct polarity. Use appropriately sized wiring and provide overcurrent protection as required by local electrical codes.
  5. 5
    System Power-Up: After all connections are verified, restore power to the cabinet and power on the Panel PC. Verify that the operating system boots correctly and the touch screen is responsive. Proceed with application software installation and configuration.

FAQ

What is the operating system on this Panel PC?

The 6AV7614-0AB32-0AF0 is pre-configured with the Windows 98 operating system in English.

What is the required input voltage for this unit?

This SIMATIC Panel PC requires a 24 V DC power supply for operation.

Does this unit include a hard drive and RAM?

Yes, this standard configuration is equipped with a 20 GB hard drive and 256 MB of RAM.

Is this product still in active production by Siemens?

No, the product lifecycle status for this model is listed as Obsolete, making it suitable for maintaining or repairing existing legacy systems.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...