Siemens

Siemens 6AV7614-0AB32-0AJ0 SIMATIC Panel PC 670

SKU 6AV7614-0AB32-0AJ0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7614-0AB32-0AJ0

  • Country of origin:Germany

  • Product Type: Industrial Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: 48 cm x 38 cm x 15 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This device is a Siemens 6AV7614-0AB32-0AJ0 SIMATIC Panel PC 670, designed for industrial human-machine interface (HMI) and control applications. It features a 15-inch TFT touch display and is powered by a Pentium III 500 MHz CPU. This standard configuration includes 256 MB of RAM, a 20 GB hard drive, and an integrated CD-ROM drive. The unit operates on a 24 V DC power supply and comes pre-installed with the Windows NT 4.0 English operating system.

Features

  • 15-inch TFT color display with touch functionality
  • Intel Pentium III processor operating at 500 MHz
  • 256 MB of installed system RAM
  • 20 GB internal hard drive for OS and application storage
  • Integrated CD-ROM optical drive
  • Nominal 24 V DC power supply input
  • Pre-loaded with Windows NT 4.0 (English version)

Applications

  • Process visualization and control
  • Machine-level data acquisition and logging
  • SCADA client terminals
  • Factory automation control panels
  • Industrial information displays

Technical Specifications

Specification Value
Model Number 6AV7614-0AB32-0AJ0
Product Series SIMATIC Panel PC 670
Display 15-inch TFT Touch Display
Processor (CPU) Pentium III, 500 MHz
Memory (RAM) 256 MB
Storage 20 GB Hard Drive (HD)
Optical Drive CD-ROM
Power Supply 24 V DC
Operating System Windows NT 4.0 (English)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Manufacturer Siemens
Country of Origin Germany (Estimated)
Package Dimensions (Calculated) 48 cm x 38 cm x 15 cm

Installation Guidelines

CRITICAL WARNING: Failure to de-energize equipment before installation can result in severe electrical shock, personnel injury, or damage to the Panel PC and connected systems. Always follow local lock-out/tag-out (LOTO) procedures.
  1. 1 Verify that the control cabinet panel cutout dimensions match the Panel PC's required mounting specifications. Ensure the mounting surface is clean, flat, and rigid.
  2. 2 De-energize the main power supply to the control cabinet and apply appropriate LOTO safety measures. Use a multimeter to confirm zero-energy state at the intended power connection points.
  3. 3 Carefully insert the Panel PC into the panel cutout from the front. Ensure the bezel gasket is properly seated against the panel surface to maintain the intended ingress protection rating.
  4. 4 From the rear of the panel, install and tighten the mounting clamps evenly in a crisscross pattern to ensure uniform pressure on the gasket. Do not overtighten.
  5. 5 Connect a low-impedance protective earth (PE) or functional ground wire to the designated grounding terminal on the Panel PC chassis. This is critical for safety and noise immunity.
  6. 6 Connect the 24 V DC power supply wiring to the unit's power input connector, ensuring correct polarity. Use appropriately sized conductors and secure the connections.
  7. 7 Connect all required communication, network (Ethernet), and peripheral (USB, serial) cables. Ensure proper cable strain relief and routing away from high-voltage lines.
  8. 8 After verifying all connections are secure, remove LOTO devices and re-energize the control cabinet. Power on the Panel PC and confirm successful boot-up and operation.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.