This is a Siemens 6AV7614-0AE32-0AE0, a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) applications. The unit features a 15-inch TFT touch display and is powered by a Pentium III 500 MHz CPU. This standard configuration includes 256 MB of RAM, a 40 GB hard drive, and operates on a 24 V DC power supply. The system comes pre-installed with a German-language version of the Windows 98 operating system.

Features

  • 15-inch TFT color display with touch functionality
  • Integrated Pentium III processor running at 500 MHz
  • Equipped with 256 MB of system RAM
  • Includes a 40 GB internal hard drive for storage
  • Operates on a nominal 24 V DC power input
  • Pre-loaded with Windows 98 operating system (German language)
  • Robust construction suitable for industrial environments

Applications

  • Machine-level operator control and monitoring
  • Process visualization and data acquisition
  • SCADA client terminals in manufacturing plants
  • Factory automation control panels
  • Data logging and recipe management

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Panel PC 670
Part Number / SKU 6AV7614-0AE32-0AE0
Display Type 15-inch TFT Touch Display
Processor (CPU) Pentium III, 500 MHz
Memory (RAM) 256 MB
Storage 40 GB Hard Drive (HD)
Power Supply Input 24 V DC
Operating System Windows 98 (German)
Product Lifecycle Status Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
ECCN N
Country of Origin Germany (Estimated)
Package Dimensions (Calculated) 48 cm x 38 cm x 15 cm

Installation Guidelines

CRITICAL WARNING: Electrical hazard. Disconnect all power sources and implement Lockout/Tagout (LOTO) procedures before installation or servicing. Installation must be performed by qualified personnel only. Failure to comply can result in severe injury or equipment damage.
  1. 1 Ensure the mounting cutout in the control cabinet or panel is prepared to the correct dimensions and is clean of debris and sharp edges. Verify adequate clearance for ventilation and cable routing behind the unit.
  2. 2 Insert the Panel PC into the cutout from the front. Secure the unit evenly using all provided mounting clamps. Tighten the clamps in a diagonal pattern to ensure a uniform seal against the panel gasket. Do not overtighten.
  3. 3 Connect a dedicated protective earth (PE) conductor to the designated grounding terminal on the PC chassis. This connection is critical for safety and noise immunity. Use a low-impedance conductor with the shortest possible path to the main cabinet ground bar.
  4. 4 Connect the 24 V DC power supply to the unit's power input connector, observing correct polarity. The power source should be a stable, regulated Safety Extra-Low Voltage (SELV) or Protective Extra-Low Voltage (PELV) supply.
  5. 5 Connect all required communication and peripheral cables (e.g., Ethernet, USB, serial). Ensure all connectors are fully seated and secured. Route cables away from high-voltage lines and sources of electromagnetic interference.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...