Siemens

Siemens 6AV7614-2AF12-0CJ0 SIMATIC Panel PC 670

SKU 6AV7614-2AF12-0CJ0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7614-2AF12-0CJ0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 0.10 x 0.10 x 0.10 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This is a Siemens 6AV7614-2AF12-0CJ0, a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) applications. The unit is equipped with a 15-inch TFT touch display and is powered by a Pentium III 500 MHz processor with 64 MByte of RAM. It includes a 40 GB hard drive, a CD-ROM drive, and comes pre-installed with the Windows NT 4.0 operating system in English. A ProTool/Pro Runtime license with 128 Power Tags is included, making it suitable for deployment in legacy control systems requiring a robust panel interface.

Features

  • 15-inch TFT color touch display for operator interaction.
  • Integrated Pentium III 500 MHz CPU.
  • Equipped with 64 MByte of system RAM.
  • Features a 40 GB hard drive and a CD-ROM optical drive.
  • Pre-loaded with Windows NT 4.0 English operating system.
  • Includes a ProTool/Pro Runtime license with 128 Power Tags.
  • Supports a wide input voltage range of 115-230V AC.

Applications

  • Legacy system HMI replacement and maintenance.
  • Machine control and process visualization.
  • Data acquisition and monitoring stations.
  • Industrial environments requiring a panel-mounted PC.

Technical Specifications

Specification Value
Manufacturer Siemens
Model Number 6AV7614-2AF12-0CJ0
Product Series SIMATIC Panel PC 670
Product Type Panel PC
Display 15-inch TFT Touch Display
Processor (CPU) Pentium III, 500 MHz
Memory (RAM) 64 MByte
Storage 40 GB Hard Drive (HD)
Optical Drive CD-ROM
Operating System Windows NT 4.0 (English)
Included Software ProTool/Pro Runtime License
Software License 128 Power Tags
Input Voltage 115-230 V
Included Power Cable European Mains Cable
Product Lifecycle Status Obsolete
Shipping Weight 12.00 kg
Country of Origin USA (estimated)
Package Dimensions (Calculated) 0.10 x 0.10 x 0.10 cm

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTRIC SHOCK

Disconnect all power sources and follow Lockout/Tagout (LOTO) procedures before installation, servicing, or removal. Installation must be performed by qualified personnel only. Failure to de-energize the system can result in severe injury or death.

  1. 1 Inspect Unit: Before installation, carefully inspect the Panel PC for any signs of shipping damage. Do not install a damaged unit. Verify the model number matches the project requirements.
  2. 2 Panel Cutout and Mounting: Prepare the enclosure or panel cutout according to the device's mechanical drawings. Ensure the mounting surface is flat and clean. Secure the Panel PC using all provided mounting clamps, tightening them evenly to create a proper seal.
  3. 3 Grounding: Connect the chassis ground terminal to the main protective earth (PE) ground of the control cabinet using a low-impedance conductor. A reliable ground connection is critical for noise immunity and safety.
  4. 4 Power Connection: Connect the mains power cable to a stable, correctly rated power source (115-230V AC). Ensure the power source is protected by an appropriate circuit breaker or fuse. Route power cables separately from communication and I/O cables.
  5. 5 System Startup: After all connections are secure and the enclosure is closed, re-apply power to the system. Verify the Panel PC boots correctly into the Windows NT operating system and that the touch screen is responsive.

FAQ

What operating system is installed on the 6AV7614-2AF12-0CJ0?

This Panel PC comes pre-installed with the Windows NT 4.0 English operating system.

What are the core hardware specifications of this unit?

It is equipped with a Pentium III 500 MHz processor, 64 MByte of RAM, and a 40 GB hard drive.

Does this Panel PC include any software licenses?

Yes, it includes a ProTool/Pro Runtime license which is enabled for 128 Power Tags.

What is the display size and type?

The unit features a 15-inch TFT touch display for operator interface and control.

What is the lifecycle status of this product?

The 6AV7614-2AF12-0CJ0 is classified as an obsolete product, primarily used for maintenance and replacement in existing legacy systems.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.