Siemens

Siemens 6AV7615-0AA20-0BF0 SIMATIC Panel PC 670

SKU 6AV7615-0AA20-0BF0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7615-0AA20-0BF0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 12g

  • Dimensions: 35.0 x 25.0 x 25.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7615-0AA20-0BF0 is a SIMATIC Panel PC 670 designed for industrial human-machine interface (HMI) and control applications. This unit features a 15-inch TFT display and is powered by a Celeron 300 MHz CPU. The standard configuration includes 128 MB of RAM and a 20 GB hard drive. It is pre-installed with the Windows 98 operating system in English and is supplied with a U.S. mains cable for operation on 115-230V power sources. Please note that this product is considered obsolete by the manufacturer, which may impact support and availability of replacement parts.

Features

  • 15-inch TFT Color Display
  • Intel Celeron 300 MHz Processor
  • 128 MB RAM
  • 20 GB Hard Drive Storage
  • Pre-installed Windows 98 Operating System (English)
  • Wide input voltage range of 115-230V AC

Applications

  • Human-Machine Interface (HMI) for process visualization
  • Supervisory Control and Data Acquisition (SCADA) nodes
  • Industrial control panel integration
  • Legacy system monitoring and control

Technical Specifications

Specification Value
Brand Siemens
Product Family SIMATIC Panel PC
Series PC670
Model Number 6AV7615-0AA20-0BF0
Display Type 15 inch TFT
CPU Celeron 300 MHz
RAM 128 MB
Storage 20 GB Hard Drive (HD)
Operating System Windows 98 (English)
Input Voltage 115-230 V
Power Cable U.S. Mains Cable
Product Lifecycle Status Obsolete
Shipping Weight 12.00 kg
Package Dimensions (Calculated) 35.0 x 25.0 x 25.0 cm
Commodity Code 85371091
ECCN N
Country of Origin (Estimated) Germany

Installation Guidelines

CRITICAL WARNING: This is an obsolete electronic device. Handle with care to prevent electrostatic discharge (ESD) damage. Ensure all power sources are de-energized and locked out/tagged out (LOTO) before installation or removal.
  1. 1 Prepare the panel cutout according to the device's mechanical dimensions. Ensure the mounting surface is clean, flat, and rigid.
  2. 2 Insert the Panel PC into the cutout from the front. Secure it from the rear using the provided mounting clamps, tightening them evenly to ensure a proper seal.
  3. 3 Connect the chassis to a dedicated protective earth (PE) or functional ground point using a low-impedance conductor to minimize electrical noise and ensure safety.
  4. 4 Connect the supplied U.S. mains power cable to the device's power input and to a stable, appropriately rated 115-230V AC power source.
  5. 5 Connect all required peripherals such as keyboards, mice, and network cables. Power on the unit and verify correct boot-up of the Windows 98 operating system.

FAQ

What operating system is installed on the 6AV7615-0AA20-0BF0?

This SIMATIC Panel PC comes pre-installed with the Windows 98 operating system in English.

What are the core processing specifications of this unit?

The device is equipped with an Intel Celeron 300 MHz CPU, 128 MB of RAM, and a 20 GB hard drive.

What is the required input voltage for this Panel PC?

The unit supports a wide input voltage range of 115-230V AC and is supplied with a U.S. mains cable.

Is this a current product from Siemens?

No, the 6AV7615-0AA20-0BF0 is classified as an obsolete product by the manufacturer. It is primarily used for maintaining or repairing existing legacy systems.

What is the screen size of this HMI panel?

This model features a 15-inch TFT display.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.