Siemens

Siemens 6AV7615-0AE12-0CE0 SIMATIC Panel PC 670

SKU 6AV7615-0AE12-0CE0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7615-0AE12-0CE0

  • Country of origin:Germany

  • Product Type: PC Panel

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: Corrections Applied: none

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7615-0AE12-0CE0 is a SIMATIC Panel PC 670, an industrial panel computer designed for human-machine interface (HMI) and control applications. This unit features a 15-inch TFT display and comes in a standard configuration with a 40 GB hard drive, 64 MBYTE RAM, and a Pentium III 500 MHz CPU. It is equipped for 115-230 V European mains power and operates with a pre-installed Windows 98 German operating system, making it suitable for integration into existing industrial automation systems requiring a robust panel-mounted computing solution.

Features

  • 15-inch TFT Display
  • Pentium III 500 MHz CPU
  • 40 GB Hard Drive
  • 64 MBYTE RAM
  • 115-230 V European Mains Power Compatibility
  • Pre-installed Windows 98 German Operating System

Applications

The Siemens SIMATIC Panel PC 670 is typically deployed in industrial environments for:

  • Machine operation and visualization
  • Process control and monitoring
  • Data acquisition and logging
  • Factory automation HMI solutions
  • Supervisory control systems

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Product Type PC panels
Display Type 15-inch TFT
Processor Pentium III 500 MHz
RAM 64 MBYTE
Hard Drive 40 GB
Power Supply 115-230 V (European Mains Cable)
Operating System Windows 98 German
Product Phase Obsolete
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Safety First: Ensure all power to the installation area is de-energized and locked out before beginning any work.
  2. Panel Cutout: Prepare the control cabinet or panel with the appropriate cutout dimensions for the Panel PC 670, ensuring sufficient clearance for ventilation and cable routing.
  3. Mounting: Insert the Panel PC into the prepared cutout from the front. Secure it using the provided mounting clamps or screws from the rear of the panel, ensuring a tight and stable fit to maintain the enclosure's integrity.
  4. Power Connection: Connect the 115-230 V AC mains power cable to the designated power input terminal on the rear of the unit. Verify correct voltage and polarity before applying power.
  5. Grounding: Ensure the Panel PC chassis is properly grounded to the control cabinet's protective earth (PE) busbar to prevent electrical hazards and ensure EMC compliance.
  6. Peripheral Connections: Connect any necessary peripherals (e.g., keyboard, mouse, network cables) to their respective ports. Route cables neatly and secure them to prevent strain or interference.
  7. Initial Power-Up: After all connections are verified, re-energize the power supply. Observe the system for proper boot-up and display functionality.

FAQ

What operating system is pre-installed on the 6AV7615-0AE12-0CE0?

The Siemens 6AV7615-0AE12-0CE0 comes with Windows 98 German pre-installed.

What are the primary display specifications of this unit?

This Panel PC features a 15-inch TFT display.

What type of power supply does the SIMATIC Panel PC 670 require?

It requires a 115-230 V AC European mains power supply.

What is the storage capacity and RAM of this Panel PC?

The unit is configured with a 40 GB hard drive and 64 MBYTE of RAM.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...