Siemens

Siemens 6AV7615-0AE22-0BH0 SIMATIC Panel PC 670 Panel PC

SKU 6AV7615-0AE22-0BH0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7615-0AE22-0BH0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 4g

  • Dimensions: Unknown (Calculated)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7615-0AE22-0BH0 is a SIMATIC Panel PC 670, an industrial panel PC designed for human-machine interface (HMI) and control applications. This unit features a 15-inch TFT display, a Pentium III 500 MHz CPU, 128 MB of RAM, and a 40 GB hard drive. It comes pre-installed with Windows NT 4.0 (German version) and is configured for 115-230 V AC power input with a U.S. mains cable, making it suitable for various industrial environments requiring a robust computing platform.

Features

  • 15-inch TFT Display
  • Pentium III 500 MHz CPU
  • 128 MB RAM
  • 40 GB Hard Drive
  • Pre-installed Windows NT 4.0 (German)
  • 115-230 V AC Power Input with U.S. Mains Cable

Applications

The SIMATIC Panel PC 670 is typically deployed in industrial settings for:

  • Human-Machine Interface (HMI) for process visualization and control
  • Data acquisition and logging
  • Supervisory control systems
  • Machine operation and monitoring
  • Production line management

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Type of Product Panel PC
PLM Product Phase Obsolete
Display Type TFT
Display Size 15 inches
Hard Drive Capacity 40 GB
RAM 128 MB
CPU Pentium III 500 MHz
Operating System Windows NT 4.0 (German)
Power Supply Voltage 115-230 V AC
Mains Cable Type U.S.
Shipping Weight 4.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N
Country of Origin Unknown
Package Dimensions (Calculated) Unknown

Installation Guidelines

  1. Safety First: Ensure all power to the installation area is de-energized before beginning any work.
  2. Mounting: Securely mount the Panel PC in a suitable industrial enclosure or panel cutout, ensuring adequate ventilation.
  3. Power Connection: Connect the 115-230 V AC power supply using the provided U.S. mains cable to a stable and protected power source. Verify correct voltage and frequency.
  4. Grounding: Establish a proper protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize EMI.
  5. Peripheral Connections: Connect any required peripherals such as keyboards, mice, or external I/O devices to the appropriate ports.
  6. Environmental Considerations: Ensure the operating environment is within the specified temperature and humidity ranges to prevent damage and ensure reliable operation. Avoid areas with excessive vibration, dust, or corrosive gases.
  7. Initial Power-Up: After all connections are verified, apply power and observe the system startup.

FAQ

What is the display size of the 6AV7615-0AE22-0BH0?

The Siemens 6AV7615-0AE22-0BH0 features a 15-inch TFT display.

What operating system is pre-installed on this Panel PC?

This Panel PC comes with Windows NT 4.0 (German version) pre-installed.

What are the power supply requirements for the 6AV7615-0AE22-0BH0?

The unit requires a 115-230 V AC power supply and includes a U.S. mains cable.

What is the CPU speed of the SIMATIC Panel PC 670?

It is equipped with a Pentium III processor running at 500 MHz.

Is the 6AV7615-0AE22-0BH0 still actively supported by Siemens?

According to the product phase information, this model is obsolete.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...