Description

The Siemens 6AV7724-3BA10-0AG0 is a SIMATIC Panel PC 670, configured as a standard industrial panel computer. This unit features a 15.1-inch color TFT display with touch functionality, making it suitable for human-machine interface (HMI) and visualization tasks in industrial environments. It is equipped with a Pentium III 1.26 GHz processor and 512 MByte SDRAM-133 (configured as 2x256MB). Storage is provided by a 40 GByte EIDE Hard Disk Drive, complemented by a DVD ROM drive. The panel PC operates on a 24V DC power supply (PS Box and Front) and comes with Windows XP Professional Multi Language pre-installed, offering a robust platform for various automation applications.

Features

  • 15.1-inch Color TFT Touch Display
  • Pentium III 1.26 GHz Processor
  • 512 MByte SDRAM-133 (2x256MB)
  • 40 GByte EIDE Hard Disk Drive
  • Integrated DVD ROM Drive
  • Pre-installed Windows XP Professional Multi Language
  • 24V DC Power Supply (PS Box and Front)

Applications

The Siemens SIMATIC Panel PC 670 is typically deployed in industrial settings requiring a robust and integrated computing solution. Common applications include:

  • Human-Machine Interface (HMI) for process control and visualization
  • Operator control and monitoring stations
  • Data acquisition and processing
  • Machine control and diagnostics
  • Factory automation systems

Technical Specifications

Manufacturer Siemens
Range Simatic Panel PC
Subrange PC670
Product Type PC panels
PLM Product Phase Obsolete
Display Type 15.1" Color TFT, Touch
Processor Pentium III 1.26 GHz
RAM 512 MByte SDRAM-133 (2x256MB)
Hard Disk Drive 40 GByte EIDE
Optical Drive DVD ROM
Operating System Windows XP Professional Multi Language
Power Supply 24V DC (PS Box and Front)
Package Dimensions (Calculated) 48.00 x 29.00 x 15.00 cm
Shipping Weight 12.00 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. De-energize System: Ensure all power to the installation area and associated equipment is disconnected before beginning installation.
  2. Mounting: Securely mount the Panel PC into the designated panel cutout or enclosure, ensuring proper ventilation clearances are maintained.
  3. Power Connection: Connect the 24V DC power supply to the appropriate terminals, observing correct polarity. Verify the power source meets the specified voltage requirements.
  4. Grounding: Establish a reliable protective earth (PE) connection to the Panel PC chassis to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect any necessary industrial peripherals (e.g., keyboards, mice, network cables, I/O) to the available interfaces.
  6. Cable Management: Route all cables to prevent strain, interference, and damage, ensuring they do not obstruct cooling vents.
  7. Power On: After all connections are verified, re-energize the system and observe for proper boot-up and operation.

FAQ

What is the display size and type of the 6AV7724-3BA10-0AG0?

The unit features a 15.1-inch color TFT display with touch functionality.

What processor and RAM configuration does this Panel PC have?

It is equipped with a Pentium III 1.26 GHz processor and 512 MByte SDRAM-133 (2x256MB).

What operating system is pre-installed on the 6AV7724-3BA10-0AG0?

The Panel PC comes with Windows XP Professional Multi Language pre-installed.

What are the power supply requirements for this device?

The Panel PC operates on a 24V DC power supply, connecting to both the PS Box and Front.

Is the Siemens 6AV7724-3BA10-0AG0 still an active product?

No, this product is listed as obsolete in its PLM Product Phase.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.