Siemens

Siemens 6AV7802-0AB22-1AB0 SIMATIC Panel PC 677 Panel PC

SKU 6AV7802-0AB22-1AB0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7802-0AB22-1AB0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371098

  • Payment: T/T, Western Union

  • Weight: 17g

  • Dimensions: 60.00 x 56.50 x 30.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7802-0AB22-1AB0 is a SIMATIC Panel PC 677 designed for industrial human-machine interface (HMI) and control applications. This unit features a 15-inch touch display with a 1024x768 resolution, powered by an Intel Pentium M 1.6 GHz processor. It is equipped with 1 GB of DDR266 SDRAM and a redundant storage system consisting of dual 60 GB hard drives configured for RAID. The system operates on a 24V DC power supply and includes a front-side USB interface for convenient peripheral access.

Features

  • 15-inch TFT touch display with 1024x768 pixel resolution
  • Intel Pentium M 770 processor operating at 1.6 GHz
  • 1 GB DDR266 SDRAM for application processing
  • Dual 60 GB hard disk drives with RAID support for data redundancy
  • Integrated DVD-ROM optical drive
  • Convenient front-panel USB interface
  • Operates on a standard 24V DC industrial power supply
  • Pre-installed with Windows 2000 Professional (Multi-language)

Applications

  • Human-Machine Interface (HMI) for process control
  • Industrial data acquisition and logging
  • Machine and plant floor visualization
  • Supervisory Control and Data Acquisition (SCADA) nodes
  • Manufacturing Execution Systems (MES) terminals

Technical Specifications

Specification Value
Model Number 6AV7802-0AB22-1AB0
Product Series SIMATIC Panel PC 677
Display Type 15-inch Touchscreen
Resolution 1024 x 768 pixels
Processor Intel Pentium M 770, 1.6 GHz
Front Side Bus (FSB) 533 MHz
Cache 2 MB SLC
Memory (RAM) 1 GB DDR266 SDRAM (1 x 1 GB)
Storage 2 x 60 GB HDD (2.5-inch) with RAID support
Optical Drive DVD-ROM
Operating System Windows 2000 Professional MUI (EN, GE, FR, IT, SP, JP, CHN, KOR)
Interfaces Front Side USB
Input Voltage 24V DC
Product Lifecycle Status Obsolete
Manufacturer Siemens
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 60.00 x 56.50 x 30.00 cm
Shipping Weight 17.00 kg
Commodity Code 85371098
ECCN N

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTRIC SHOCK

Disconnect all power sources before installation or maintenance. This equipment must be installed and serviced by qualified personnel only. Adhere to all local and national safety regulations, including Lockout/Tagout (LOTO) procedures.

  1. 1
    Panel Cutout and Mounting: Prepare the control cabinet or panel cutout according to the manufacturer's specified dimensions. Ensure the mounting surface is flat and clean. Insert the Panel PC into the cutout and secure it evenly using all provided mounting clamps to maintain the specified IP rating. Do not overtighten.
  2. 2
    Protective Earth (PE) Connection: Connect the designated grounding terminal on the Panel PC chassis to the main protective earth conductor of the control cabinet. Use a low-impedance connection with a wire of appropriate gauge to ensure personnel safety and reduce electromagnetic interference (EMI).
  3. 3
    Power Supply Connection: Connect a stable, regulated 24V DC power source to the power input terminals. Verify correct polarity (+/-) before applying power. It is recommended to use a dedicated, isolated power supply unit (PSU) rated for industrial environments.
  4. 4
    Peripheral and Network Connections: Connect all required peripherals, such as keyboards, mice, or USB devices, and network cables. Ensure all cable connections are secure and properly seated. Route cables away from high-voltage lines to minimize noise induction.
  5. 5
    System Power-Up: After verifying all connections are correct and secure, re-energize the main power supply. Power on the Panel PC and observe the boot sequence to ensure the operating system loads correctly. Proceed with application-specific software configuration.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...