Siemens

Siemens 6AV7812-0AC10-1AB0 SIMATIC Panel PC 877

SKU 6AV7812-0AC10-1AB0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6AV7812-0AC10-1AB0

  • Country of origin:Germany

  • Product Type: Panel PC

  • Barcode: 85371098

  • Payment: T/T, Western Union

  • Weight: 17g

  • Dimensions: 60.00 x 56.50 x 30.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6AV7812-0AC10-1AB0 is a SIMATIC Panel PC 877 designed for industrial human-machine interface (HMI) applications. This unit features a 15-inch touchscreen display with a 1024 x 768 pixel resolution and a convenient front-side USB port. It is powered by a Pentium 4 Mobile 2.2 GHz processor and is equipped with 512 MB of DDR266 SDRAM and a 40 GB EIDE hard drive. The system comes pre-installed with Windows 2000 Professional Multi-Language User Interface (MUI) and includes a DVD-ROM drive for software installation and data access. This model requires a 24V DC power source for operation.

Features

  • ■15-inch color touchscreen display
  • ■Pentium 4 Mobile 2.2 GHz processor
  • ■512 MB DDR266 SDRAM
  • ■40 GB EIDE hard disk drive (3.5-inch)
  • ■Integrated DVD-ROM drive
  • ■Front-accessible USB interface
  • ■Operates on a 24V DC power supply
  • ■Pre-installed Windows 2000 Professional MUI

Applications

  • ■Process visualization and control
  • ■Machine-level operator interfaces
  • ■Industrial data acquisition and logging
  • ■Factory automation systems

Technical Specifications

Manufacturer Siemens
Part Number 6AV7812-0AC10-1AB0
Product Series SIMATIC Panel PC 877
Product Type Panel PC
Display Size 15-inch Touchscreen
Resolution 1024 x 768 pixels
Processor Pentium 4 Mobile, 2.2 GHz
Front Side Bus (FSB) 400 MHz
Cache 512 KB SLC
Memory (RAM) 512 MB DDR266 SDRAM (1x 512MB)
Storage 40 GB EIDE HDD (3.5-inch)
Optical Drive DVD-ROM
Operating System Windows 2000 Professional MUI (EN, GE, FR, IT, SP, JP, CHN, KOR)
Power Supply 24V DC
Product Lifecycle Status Obsolete
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 60.00 x 56.50 x 30.00 cm
Shipping Weight 17.00 kg
Commodity Code 85371098
ECCN N

Installation Guidelines

CRITICAL WARNING: Hazardous voltages can cause severe injury or death. Disconnect and lock out all power sources to the enclosure before installation or removal. Installation must be performed by qualified personnel only.

  1. 1 Verify that the panel cutout dimensions match the unit's specifications for a proper fit and seal. Ensure the mounting surface is clean, flat, and rigid.
  2. 2 Insert the Panel PC into the cutout from the front of the enclosure. Secure it from the rear using all provided mounting clamps, tightening them evenly to the manufacturer's recommended torque to ensure a uniform seal.
  3. 3 Connect the protective earth (PE) or grounding terminal to the enclosure's main ground point using a low-impedance conductor. A reliable ground connection is essential for safety and noise immunity.
  4. 4 Connect the 24V DC power supply, ensuring correct polarity. Use appropriately sized wiring for the current draw and route power cables separately from high-voltage or communication lines to prevent interference.
  5. 5 Connect all required communication and I/O cables. Ensure all connectors are fully seated and secured. Provide adequate strain relief for all cabling.

FAQ

What operating system is installed on the 6AV7812-0AC10-1AB0?

This Panel PC comes pre-installed with Windows 2000 Professional Multi-Language User Interface (MUI), supporting English, German, French, Italian, Spanish, Japanese, Chinese, and Korean.

What is the screen size and resolution?

The unit features a 15-inch touchscreen display with a native resolution of 1024 x 768 pixels.

What is the required input voltage for this device?

The Siemens 6AV7812-0AC10-1AB0 requires a 24V DC power supply for operation.

Does this model have an optical drive?

Yes, it is equipped with an integrated DVD-ROM drive.

Is this Panel PC a current product?

No, this model is designated as an obsolete product in the manufacturer's product lifecycle. It is suitable for replacement or spare parts purposes.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.