Siemens

Siemens 6DS1403-8CB Teleperm Controller Module

SKU 6DS1403-8CB

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6DS1403-8CB

  • Country of origin:Germany

  • Product Type: Controller Module

  • Barcode: 85389091

  • Payment: T/T, Western Union

  • Weight: 510g

  • Dimensions: 26.20cm x 20.80cm x 4.50cm

  • Shipping port: Xiamen

  • Warranty: 12 months

The 6DS1403-8CB is a specialized controller module from the Siemens TELEPERM series, engineered for precise closed-loop process control. This unit features two integrated PI (Proportional-Integral) controllers with 2-channel functionality. A key technical feature is the support for the NAMUR failure signal level, specifically configured for a range of 3.6 mA to 21 mA. This capability ensures reliable signal monitoring and fault detection in industrial control loops.

Features

  • Control Type: Dual PI (Proportional-Integral) closed-loop controllers.
  • Channel Configuration: 2-channel control architecture.
  • Signal Compatibility: Supports NAMUR failure signal level standard (3.6 mA/21 mA).
  • Architecture: Designed for seamless integration into TELEPERM control systems.
  • Reliability: Built to maintain stable process regulation in demanding industrial environments.

Applications

  • Process automation in chemical and manufacturing plants.
  • Closed-loop regulation of temperature, pressure, or flow control loops.
  • Integration into legacy TELEPERM automation architectures.
  • Industrial monitoring systems requiring NAMUR signal fault detection.

Technical Specifications

Attribute Specification
Manufacturer Siemens
Product Range Teleperm
Controller Type 2 x PI Controls
Channels 2-channel
Failure Signal Level NAMUR (3.6 mA / 21 mA)
Dimensions (WxHxD) 26.20 x 20.80 x 4.50 cm
Weight 0.51 kg
Commodity Code 85389091

Installation Guidelines

  • Mounting: Install the module in a suitable rack or housing designed for the TELEPERM series. Ensure secure engagement with the backplane connectors to maintain stable electrical contact.
  • Signal Wiring: Adhere to standard instrumentation wiring practices for 4-20 mA loops. Verify that the current signal output falls within the 3.6 mA to 21 mA range to correctly trigger NAMUR fault signaling.
  • Environment: Protect the module from exposure to excessive heat, moisture, or corrosive industrial atmospheres to prevent premature degradation of electronic components.
  • Calibration: Periodically verify the PI control parameters and signal thresholds to ensure the control loop maintains specified performance accuracy.

FAQ

What does the NAMUR signal level support imply for this module?

It allows the module to detect and signal fault conditions specifically within the 3.6 mA to 21 mA range, following industry-standard NAMUR failure signaling.

How many control channels does the 6DS1403-8CB provide?

This module features 2 channels with dual PI controllers.

Is the 6DS1403-8CB suitable for modern automation systems?

This is part of the legacy Teleperm series and is primarily used for maintenance or replacement within existing TELEPERM-based control architectures.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Dots
Country of origin
Germany
Power source
DC Power

Technical knowledge

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.