Siemens

Siemens 6ES5581-0EA11 SIMATIC S5 CP 581 Basic Module

SKU 6ES5581-0EA11

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES5581-0EA11

  • Country of origin:Germany

  • Product Type: Basic Module

  • Barcode: 85389091

  • Payment: T/T, Western Union

  • Weight: 630g

  • Dimensions: 15.40 x 13.20 x 9.10 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES5581-0EA11 is a SIMATIC S5 CP 581 basic module equipped with 4 MBYTE working memory. Designed for integration into industrial automation systems, this module supports efficient communication and process control within production environments. It is engineered for compatibility with the SIMATIC S5 system, specifically within the S5-135/155 range, making it suitable for maintaining or upgrading existing production lines. With its robust construction and dependable performance, the 6ES5581-0EA11 contributes to minimizing downtime and ensuring smooth operation in industrial settings. The 4 MBYTE working memory facilitates efficient data processing, ensuring compatibility and durability as a genuine Siemens product.

Features

  • SIMATIC S5 CP 581 basic module
  • 4 MBYTE working memory
  • Compatible with SIMATIC S5 system (S5-135/155 range)
  • Supports efficient communication and process control
  • Robust construction for industrial environments

Applications

  • Industrial automation systems
  • Process control within production environments
  • Maintaining or upgrading existing SIMATIC S5 production lines
  • Environments requiring dependable and quick-to-deploy solutions

Technical Specifications

Parameter Value
Manufacturer Siemens
Brand Siemens
Range SIMATIC S5
Subrange S5-135/155
Product Type Basic Module
Working Memory 4 MBYTE
Product Phase Obsolete
Package Dimensions (Calculated) 15.40 x 13.20 x 9.10 cm
Shipping Weight 0.63 kg
Commodity Code 85389091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Ensure the SIMATIC S5 system and associated power supplies are completely de-energized and locked out before commencing installation.
  2. Mount the 6ES5581-0EA11 module securely into the designated slot within the SIMATIC S5 rack or chassis.
  3. Verify that the module is fully seated to ensure proper electrical contact with the backplane.
  4. Connect all necessary system and communication cables according to the overall system architecture and wiring diagrams.
  5. Ensure adequate clearance and ventilation around the module to prevent overheating during operation.
  6. Adhere to all local and national electrical safety codes and regulations during the entire installation and commissioning process.

FAQ

What is the primary function of the 6ES5581-0EA11?

It functions as a basic module within the SIMATIC S5 CP 581 system, providing 4 MBYTE of working memory for process control and communication.

Which SIMATIC S5 systems is this module compatible with?

The module is compatible with the SIMATIC S5 system, specifically designed for integration within the S5-135/155 range.

What is the working memory capacity of this module?

The 6ES5581-0EA11 is equipped with 4 MBYTE of working memory.

Is the 6ES5581-0EA11 still actively manufactured?

According to its product phase, this module is classified as obsolete.

What are the physical dimensions and weight of the module?

The module measures 15.40 x 13.20 x 9.10 cm and has a shipping weight of 0.63 kg.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 7
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...

Seal-In Logic or OTL/OTU? Choosing PLC Memory Safely

Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...

Commissioning a Micro800 PLC in FactoryTalk Design Workbench

A practical Micro800 commissioning workflow covering hardware checks, USB and Ethernet discovery, safe ladder testing, download risks, fault isolation, and project recovery in FactoryTalk Design...

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.