Siemens

Siemens 6ES7315-6TG10-0AB0 SIMATIC S7-300 CPU 315T-2 DP

SKU 6ES7315-6TG10-0AB0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7315-6TG10-0AB0

  • Country of origin:Germany

  • Product Type: Central Processing Unit

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 600g

  • Dimensions: 17.80 x 12.70 x 15.20 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7315-6TG10-0AB0 is a SIMATIC S7-300 CPU 315T-2 DP, a central processing unit engineered for advanced automation tasks within industrial environments. This CPU is equipped with 128 KByte working memory, facilitating efficient data processing for complex production processes. It features two high-speed communication interfaces: a primary MPI/DP interface supporting data rates up to 12 Mbit/s, and a dedicated DP (Drive) interface for seamless integration with drives and other field devices. Integrated I/O for technology applications is accessible via a 40-pin front connector, which simplifies installation and maintenance within control cabinets. The 6ES7315-6TG10-0AB0 requires a minimum 4MB Micro Memory Card for operation, making it a robust and dependable solution for evolving manufacturing needs.

Features

  • 128 KByte working memory
  • Integrated MPI/DP interface with 12 Mbit/s data rate
  • Dedicated DP (Drive) interface for drive communication
  • Integrated I/O for technology applications
  • Single 40-pin front connector for I/O access
  • Requires minimum 4MB Micro Memory Card

Applications

  • Advanced automation tasks in manufacturing
  • Control systems for complex production processes
  • Integration with industrial drives and field devices
  • General PLC control within the SIMATIC S7-300 platform

Technical Specifications

Parameter Value
Manufacturer Siemens
Brand Siemens
Range Simatic S7
Subrange S7-300
Product Type Standard CPUs, CPU 315T-2 DP
PLM Product Phase Obsolete
Working Memory 128 KByte
Interface 1 MPI/DP, 12 Mbit/s
Interface 2 DP (Drive)
Integrated I/O Connector 1 x 40-pin front connector
Memory Card Requirement Minimum 4MB Micro Memory Card
Package Dimensions (Calculated) 17.80 x 12.70 x 15.20 cm
Shipping Weight 0.60 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Connections / Interfaces

Interface Type Description
MPI/DP Multi-Point Interface / Distributed Periphery, 12 Mbit/s
DP (Drive) Dedicated Distributed Periphery interface for drive communication
Front Connector 1 x 40-pin connector for integrated I/O
Micro Memory Card Slot For program and data storage, requires minimum 4MB card

Installation Guidelines

  1. Safety First: Ensure all power to the rack or control cabinet is de-energized and locked out before beginning installation.
  2. Mounting: Insert the CPU module into the designated slot on the SIMATIC S7-300 rack. Ensure it is securely seated and locked into place using the module's retaining clips.
  3. Memory Card Insertion: Carefully insert a Micro Memory Card (minimum 4MB) into the designated slot on the CPU. Ensure it clicks into place.
  4. Front Connector Attachment: Connect the 40-pin front connector to the CPU for integrated I/O. Verify that all wiring to the connector is correct and secure according to your system's wiring diagrams.
  5. Communication Cabling: Connect the MPI/DP and DP (Drive) communication cables to their respective ports on the CPU. Ensure proper termination and shielding for optimal signal integrity.
  6. Power-Up: After all connections are verified, re-energize the system. Observe the CPU's status LEDs for proper operation.
  7. Configuration: Use appropriate Siemens engineering software (e.g., STEP 7) to configure the CPU, load the application program, and set up communication parameters.

FAQ

What is the working memory capacity of the 6ES7315-6TG10-0AB0?

The CPU 315T-2 DP is equipped with 128 KByte of working memory.

What communication interfaces are available on this CPU?

It features an MPI/DP interface with 12 Mbit/s and a dedicated DP (Drive) interface for communication with drives.

What type of memory card is required for operation?

The CPU requires a Micro Memory Card with a minimum capacity of 4MB.

How is the integrated I/O accessed?

Integrated I/O for technology applications is accessible via a 40-pin front connector.

Is this CPU suitable for connecting to industrial drives?

Yes, it includes a dedicated DP (Drive) interface designed for seamless communication with industrial drives.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 7
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.