Siemens

Siemens 6ES7321-1BH01-0AA0 SIMATIC S7-300 Digital Input Module

SKU 6ES7321-1BH01-0AA0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7321-1BH01-0AA0

  • Country of origin:Germany

  • Product Type: Digital Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 240g

  • Dimensions: 12.5 x 10.5 x 4.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7321-1BH01-0AA0 is a digital input module designed for the SIMATIC S7-300 PLC system. This module provides 16 optically isolated input channels for reliable signal acquisition from field devices operating at 24V DC. It is engineered to interface with sensors, switches, and other discrete signal sources in industrial automation environments. The module's optical isolation protects the PLC backplane from electrical disturbances and ground loops originating in field wiring, enhancing overall system stability and safety. Its compact, high-density design conserves valuable control cabinet space while a single 20-pin connector simplifies wiring and installation.

Features

  • 16 digital input channels
  • Rated input voltage of 24V DC
  • Optical isolation between field and logic circuits
  • Compatible with the Siemens SIMATIC S7-300 series
  • Single 20-pin front connector for simplified wiring

Applications

  • Manufacturing and assembly lines
  • Conveyor and material handling systems
  • Packaging and bottling machinery
  • Process control signal acquisition

Technical Specifications

Specification Value
Manufacturer Siemens
Model Number 6ES7321-1BH01-0AA0
Product Family SIMATIC S7-300
Module Type Digital Input Module
Number of Inputs 16
Input Voltage 24V DC
Isolation Optically Isolated
Connector Type 20-pin
Lifecycle Status Active
Country of Origin Germany
HS Code 8537101190
Shipping Weight 0.24 kg
Package Dimensions (Calculated) 12.5 x 10.5 x 4.0 cm

Installation Guidelines

CRITICAL WARNING: Hazardous voltages may be present. Installation must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe injury or death. Always follow local Lockout/Tagout (LOTO) procedures.
  1. 1 De-energize the S7-300 rack and verify the absence of voltage using a calibrated multimeter. Apply appropriate LOTO devices.
  2. 2 Select an available slot on the S7-300 backplane. Align the module with the backplane bus connectors and press firmly until it is securely seated.
  3. 3 Secure the module to the DIN rail by tightening the integrated mounting screw located on the front of the module. Do not overtighten.
  4. 4 Prepare and terminate field wiring onto the 20-pin front connector according to the system wiring diagrams. Ensure proper wire gauge and ferrule usage.
  5. 5 Plug the front connector into the module, ensuring it is fully seated and secured by its locking mechanism.
  6. 6 After verifying all connections are correct and secure, remove LOTO devices and re-energize the system for commissioning.

FAQ

What PLC system is the 6ES7321-1BH01-0AA0 compatible with?

This module is designed for use with the Siemens SIMATIC S7-300 PLC system.

How many input channels does this module have?

The module features 16 digital input channels.

What is the rated input voltage for the channels?

The channels are rated for a 24V DC input voltage.

Are the inputs on this module isolated?

Yes, all 16 input channels are optically isolated from the PLC backplane to protect against electrical disturbances.

What type of connector is used for field wiring?

The module uses a single 20-pin front connector for all field wiring terminations.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.