Siemens

Siemens 6ES7478-2DX00-0AA0 SIMATIC Connection TBX478 Interface Module

SKU 6ES7478-2DX00-0AA0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7478-2DX00-0AA0

  • Country of origin:Germany

  • Product Type: Interface Modules

  • Barcode: 85389091

  • Payment: T/T, Western Union

  • Weight: 750g

  • Dimensions: 25.00cm x 18.00cm x 5.25cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Overview

The 6ES7478-2DX00-0AA0 (6ES74782DX000AA0) is a specialized connection terminal block (TBX478) designed for high-level interface operations within the SIMATIC industrial automation ecosystem. This module is specifically engineered to facilitate the connection for the Input/Output-Bus, providing the necessary interface for I/O-Bus 1 and 2. It is a mandatory system component that functions exclusively in combination with the TPM478 (Terminal Processor Module). Together, they provide the robust data throughput and signal synchronization required for complex, high-speed PLC processing environments.


Detailed Specifications

Feature Technical Data
Manufacturer Siemens
Model Number 6ES7478-2DX00-0AA0
Product Family SIMATIC Interface Modules
Module Type Connection TBX478 (Terminal Block)
Bus Compatibility I/O-Bus 1 / I/O-Bus 2
Required Pairing TPM478 (Mandatory for operation)
Dimensions (W x H x D) 180 mm x 250 mm x 52.5 mm
Net Weight 0.75 kg (Approx. 1.65 lbs)
Product Phase Obsolete (Legacy Support Only)
Commodity Code 85389091
ECCN Regulation N (Non-restricted)

Operational Capabilities

The 6ES7478-2DX00-0AA0 serves as a critical junction point for the I/O-Bus communication layer. In large-scale Siemens configurations, it ensures that data packets between the processor and the distributed periphery remain consistent and interference-free. Due to its "Obsolete" status, this module is primarily used in maintenance and repair cycles for existing industrial lines where the TPM478/TBX478 architecture is already established. Its robust mechanical design allows it to withstand the thermal and vibrational stresses typical of centralized control cabinets.

Technical FAQ

Can I use the 6ES7478-2DX00-0AA0 as a standalone interface?

No. The module is non-functional without the TPM478 module. It serves as the physical connection interface (TBX) for the logic processing performed by the TPM.

What is the primary function of the I/O-Bus 1/2 interface?

This interface manages the high-speed exchange of digital and analog signals between the central controller and specific specialized I/O racks, ensuring that time-critical production data is prioritized.

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Germany
Power source
DC Power

Technical knowledge

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.