Siemens

Siemens 6ES7647-5AG00-2HX0 SIMATIC Box PC 620 Industrial PC

SKU 6ES7647-5AG00-2HX0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7647-5AG00-2HX0

  • Country of origin:Germany

  • Product Type: Industrial PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 7050g

  • Dimensions: 45.00 x 47.50 x 27.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7647-5AG00-2HX0 is a SIMATIC Box PC 620 industrial computer designed for robust operation in automation environments. This unit features an onboard AGP graphics controller with configurable memory, a 10/100 Mbit/s Ethernet interface, and a PC Card (PCMCIA Type 3) slot for expansion. It includes essential industrial features such as a watchdog timer and temperature monitoring. Processing power is provided by a Celeron 566 MHz processor, complemented by 64 MB of SDRAM-133 RAM and a 40 GB EIDE hard disk drive. Connectivity options include two USB ports, PROFIBUS/MPI, and TTY interfaces, along with PCI and ISA/PCI expansion slots. The unit is powered by a 24 V DC industry power supply and comes with Windows 98 SE German pre-installed.

Features

  • AGP Graphics Onboard with 8/16/32 MB configurable memory
  • 10/100 Mbit/s Ethernet via RJ45 interface
  • PC Card (PCMCIA Type 3) slot
  • Integrated Watchdog and Temperature Monitoring functions
  • 2 x USB ports
  • 1 x PCI expansion slot
  • 1 x ISA/PCI free expansion slot
  • Celeron 566 MHz Processor with 128 KB SLC cache
  • PROFIBUS/MPI 12 Mbit/s communication interface
  • TTY interface
  • 40 GB EIDE Hard Disk Drive
  • 64 MB SDRAM-133 RAM
  • 1.44 MB, 3.5" Floppy Drive
  • 24 V DC, 85 A Industry Power Supply
  • Pre-installed Windows 98 SE German (without expansion)

Applications

The Siemens SIMATIC Box PC 620 is suitable for a wide range of industrial applications requiring a reliable and compact computing platform. Typical uses include:

  • Machine control and visualization systems
  • Process data acquisition and monitoring
  • Operator interface (HMI) solutions
  • Industrial networking and communication gateways
  • Embedded control systems in manufacturing and automation

Technical Specifications

Attribute Value
Brand Siemens
Manufacturer Siemens
Range Simatic Box PC
Subrange PC620
Product Type Industrial PC / PC box
Processor Celeron 566 MHz
Processor Cache 128 KB SLC
RAM 64 MB SDRAM-133
Hard Drive 40 GB HDD EIDE
Floppy Drive 1.44 MB, 3.5"
Graphics AGP Onboard, 8/16/32 MB configurable
Ethernet 10/100 Mbit/s RJ45
Communication Interfaces PROFIBUS/MPI 12 Mbit/s, TTY
Expansion Slots 1 x PCI, 1 x ISA/PCI free
Other Interfaces 2 x USB, PC Card (PCMCIA Type 3)
Power Supply 24 V DC, 85 A Industry Power Supply
Operating System Windows 98 SE German (without expansion)
Monitoring Watchdog, Temperature Monitoring
Product Phase Phase-Out
Package Dimensions (Calculated) 45.00 x 47.50 x 27.00 cm
Shipping Weight 7.05 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Connections / Interfaces

Connector Type Function / Specification
RJ45 10/100 Mbit/s Ethernet
USB 2 x Universal Serial Bus ports
PC Card Type 3 (PCMCIA) slot
PROFIBUS/MPI 12 Mbit/s communication interface
TTY Serial communication interface
PCI 1 x Peripheral Component Interconnect slot
ISA/PCI 1 x shared ISA/PCI expansion slot

Installation Guidelines

  1. De-energize System: Before installation, ensure all power to the system and associated equipment is disconnected and locked out.
  2. Mounting: Securely mount the Box PC in a suitable industrial enclosure or rack, ensuring adequate ventilation and clearance for cable routing and maintenance.
  3. Power Connection: Connect the 24 V DC power supply to the designated power input terminals, observing correct polarity. Verify the power supply can provide the required 85 A current.
  4. Grounding: Establish a proper protective earth (PE) connection to the chassis of the Box PC to ensure electrical safety and minimize electromagnetic interference.
  5. Peripheral Connections: Connect necessary peripherals such as display monitors, keyboards, and mice to the appropriate USB or other interface ports.
  6. Network Connections: Connect Ethernet cables to the RJ45 port for network communication. For PROFIBUS/MPI and TTY, connect the respective communication cables.
  7. Expansion Cards: If using expansion cards, carefully insert them into the available PCI or ISA/PCI slots, ensuring they are properly seated and secured.
  8. Cable Management: Route all cables neatly and securely, separating power and signal cables where possible to reduce interference. Use cable ties or clamps as needed.
  9. Environmental Check: Ensure the operating environment meets the specified temperature and humidity ranges for industrial PCs to prevent premature failure.
  10. Power Up: Once all connections are verified, re-energize the system and monitor for proper boot-up and operation.

FAQ

What operating system is pre-installed on the SIMATIC Box PC 620?

The Siemens 6ES7647-5AG00-2HX0 comes with Windows 98 SE German pre-installed, without expansion.

What type of processor does this industrial PC use?

It is equipped with a Celeron 566 MHz processor, featuring 128 KB of SLC cache.

What are the primary communication interfaces available?

The PC includes a 10/100 Mbit/s Ethernet RJ45 port, PROFIBUS/MPI at 12 Mbit/s, and a TTY interface.

Can I expand the functionality of this Box PC?

Yes, it features a PC Card (PCMCIA Type 3) slot, one PCI slot, and one free ISA/PCI shared slot for expansion cards.

What are the power requirements for the 6ES7647-5AG00-2HX0?

The unit requires a 24 V DC industry power supply capable of providing 85 A.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 10
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...

Seal-In Logic or OTL/OTU? Choosing PLC Memory Safely

Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...

Commissioning a Micro800 PLC in FactoryTalk Design Workbench

A practical Micro800 commissioning workflow covering hardware checks, USB and Ethernet discovery, safe ladder testing, download risks, fault isolation, and project recovery in FactoryTalk Design...

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.