Siemens

Siemens 6ES7647-6AB25-0CJ0 SIMATIC BOX PC 627 Industrial PC

SKU 6ES7647-6AB25-0CJ0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7647-6AB25-0CJ0

  • Country of origin:Germany

  • Product Type: Industrial PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 7050g

  • Dimensions: 92.0 x 21.0 x 14.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This product is a Siemens 6ES7647-6AB25-0CJ0, a SIMATIC BOX PC 627 designed for industrial applications. It is equipped with a Celeron M 370 1.5 GHz processor, 512 MB of DDR2 RAM, and an 80 GB SATA hard drive. Connectivity options include dual 10/100 Mbit/s Ethernet, four high-current USB 2.0 ports, a serial port, and an integrated PROFIBUS/MPI interface. The system features onboard AGP graphics, a RAID controller, and monitoring functions for temperature and fan status. This unit is powered by a 24V DC industrial power supply and comes pre-installed with Windows 2000 Professional.

Features

  • Celeron M 370 processor operating at 1.5 GHz with a 400 MHz FSB.
  • 512 MB DDR2 533 SODIMM system memory.
  • Integrated AGP graphics with 8-128 MB of shared memory.
  • 80 GB SATA Hard Disk Drive and a DVD+/-RW optical drive.
  • Dual 10/100 Mbit/s Ethernet RJ45 ports for network connectivity.
  • Built-in PROFIBUS/MPI interface for industrial communication.
  • Onboard RAID controller for data redundancy.
  • System monitoring including watchdog timer, temperature, and fan status.
  • Two available PCI slots for expansion.

Applications

  • Human-Machine Interface (HMI) and SCADA systems.
  • Data acquisition and logging in manufacturing environments.
  • PC-based control and automation tasks.
  • Gateway for industrial network communications.
  • Process visualization and monitoring stations.

Technical Specifications

Specification Value
Product Type SIMATIC BOX PC 627
Processor Celeron M 370, 1.5 GHz, 400 MHz FSB, 1 MB SLC
Memory 512 MB DDR2 533 SODIMM
Graphics AGP Onboard, 8-128 MB Shared Memory
Storage 80 GB HDD SATA, DVD+/-RW
Removable Media 1x Slot for Compact Flash Drive
Expansion Slots 2x PCI (free)
Interfaces 2x 10/100 Mbit/s Ethernet (RJ45), 4x USB V2.0 (High Current), 1x Serial (COM1), 1x PROFIBUS/MPI
Power Supply 24V DC Industrial Power Supply
Operating System Windows 2000 Professional Multi-Language SP4 (EN, GE, FR, IT, SP)
System Monitoring Watchdog, Temperature/Fan Monitoring
PLM Product Phase Obsolete
Manufacturer Siemens
Country of Origin Germany (Estimate)
Shipping Weight 7.05 kg
Package Dimensions (Calculated) 92.0 x 21.0 x 14.0 cm

Installation Guidelines

CRITICAL WARNING: Hazardous voltages may be present. Installation must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe injury or death. Always adhere to local Lockout-Tagout (LOTO) procedures.
  1. 1
    De-energize Equipment: Before installation, completely de-energize the control cabinet and verify the absence of voltage using a calibrated multimeter. Follow all site-specific LOTO safety procedures.
  2. 2
    Mount the Chassis: Securely mount the BOX PC chassis to the designated panel or mounting surface. Ensure adequate clearance around the unit for proper ventilation and heat dissipation.
  3. 3
    Connect System Ground: Connect a dedicated protective earth (PE) conductor to the chassis ground terminal. A low-impedance ground connection is critical for safety and noise immunity.
  4. 4
    Connect Power Supply: Connect the 24V DC power source to the designated power input terminals. Verify correct polarity (+/-) before applying power to prevent damage to the unit.
  5. 5
    Terminate I/O and Network Cables: Connect all required communication cables, such as Ethernet, PROFIBUS, USB, and serial devices. Ensure all connectors are fully seated and secured.
  6. 6
    System Power-Up: After verifying all connections, remove the LOTO device and re-energize the cabinet. Power on the BOX PC and verify correct boot-up and system operation.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.