Description
This Siemens 6ES7647-6CA16-1XX0 is a SIMATIC IPC627C series industrial box PC, designed for robust performance in demanding automation environments. It is equipped with a Celeron P4505 1.86 GHz processor, 2 GB of DDR3 RAM, and an integrated RAID controller for data integrity. The unit operates on a 24 V DC industrial power supply and features onboard system monitoring for temperature, fans, and a watchdog timer. This specific configuration is delivered without storage drives or an operating system, providing a flexible platform for custom industrial applications.
Features
- Processor: Intel Celeron P4505 (2 Cores, 2 Threads, 1.86 GHz)
- Memory: 2 GB DDR3 1066 DIMM
- Power Supply: 24 V DC Industrial Input
- Ethernet: Dual 10/100/1000 Mbit/s RJ45 ports
- USB Ports: Four high-current USB 2.0 ports
- Serial Port: One COM1 serial interface
- Storage: Onboard RAID controller and front-accessible CompactFlash drive slot
- Expansion: One PCI slot and one PCIe (x16) slot
- System Monitoring: Integrated watchdog, temperature, and fan monitoring
- Graphics: Onboard HD graphics controller
Applications
- Human-Machine Interface (HMI) server
- Data acquisition and logging gateway
- Process control and visualization nodes
- Industrial network communication hub
- Shop-floor manufacturing execution systems (MES)
Technical Specifications
| Specification |
Value |
| Product Type |
SIMATIC IPC627C (Box PC) |
| Processor |
Celeron P4505 (2C/2T, 1.86 GHz, VT, 2 MB cache) |
| Memory |
2 GB DDR3 1066 DIMM |
| Power Supply |
24 V DC |
| Ethernet Ports |
2 x 10/100/1000 Mbit/s Ethernet RJ45 |
| USB Ports |
4 x USB V2.0 (high current) |
| Serial Port |
1 x COM1 |
| Expansion Slots |
1 x PCI, 1 x PCIe (x16) |
| Storage Interface |
CompactFlash Drive (front), Onboard RAID controller |
| Supplied Configuration |
Without drives, without operating system |
| Product Lifecycle Status |
Phase-Out |
| Shipping Weight |
6.30 kg |
| Package Dimensions (Calculated) |
45 cm x 35 cm x 25 cm |
| Country of Origin |
Germany (Estimate) |
| Manufacturer |
Siemens |
Installation Guidelines
CRITICAL WARNING: Electrical Hazard
Disconnect all power sources before installation or maintenance. This equipment is intended for use by qualified personnel only. Failure to de-energize the system can result in severe injury or death.
-
1
Verify adequate clearance around the PC for proper airflow and heat dissipation. Do not block ventilation openings.
-
2
Securely mount the chassis to a stable, vibration-free panel or surface using all designated mounting points.
-
3
Connect a low-impedance protective earth (PE) conductor to the designated chassis grounding terminal. This is critical for safety and noise immunity.
-
4
Connect the 24V DC power supply, ensuring correct polarity. Use appropriately sized conductors for the load and distance.
-
5
Connect network, USB, and serial communication cables. Ensure proper shielding and grounding practices are followed for all I/O cables.