Description
The Siemens 6ES7647-6CE06-0HA0 is a SIMATIC IPC627C Box PC designed for industrial applications requiring robust computing power and connectivity. This unit features onboard HD graphics, two 10/100/1000 Mbit/s Ethernet RJ45 ports, four USB V2.0 ports with high current capability, and one serial (COM 1) interface. It integrates an onboard RAID controller and includes a CompactFlash drive slot on the front for flexible storage options. The system is equipped with a Watchdog function and temperature/fan monitoring for enhanced reliability.
Powered by an Intel Core i3-330E processor (2 cores/4 threads, 2.13 GHz, with Hyper-Threading and Virtualization Technology, 3 MB cache), the 6ES7647-6CE06-0HA0 also supports PROFIBUS/MPI communication via a CP 5611-A2-compatible interface. It comes with 2 MB of buffered RAM and 1 GB DDR3 1066 DIMM system memory. The unit operates on a 24 V DC industrial power supply and offers two free PCI slots for expansion. Storage is handled by a RAID1 configuration with two 320 GB SATA (2.5") drives, complemented by a DVD +/-RW optical drive. The system is pre-installed with Windows XP Professional SP3 MUI (Multi-User Interface) supporting German, English, French, Spanish, and Italian languages.
Features
- Integrated HD Graphics
- Dual 10/100/1000 Mbit/s Ethernet RJ45 Ports
- Four USB V2.0 Ports (High Current)
- One Serial (COM 1) Interface
- Onboard RAID Controller
- Front-accessible CompactFlash Drive Slot
- Watchdog and Temperature/Fan Monitoring
- Intel Core i3-330E Processor (2C/4T, 2.13 GHz, HT, VT, 3 MB Cache)
- PROFIBUS/MPI (CP 5611-A2-compatible)
- 2 MB Buffered RAM
- 1 GB DDR3 1066 DIMM System Memory
- 24 V DC Industrial Power Supply
- Two Free PCI Expansion Slots
- RAID1 Configuration with 2x 320 GB SATA (2.5") Drives
- DVD +/-RW Optical Drive
- Pre-installed Windows XP Professional SP3 MUI
Applications
The Siemens SIMATIC IPC627C Box PC is suitable for a wide range of industrial automation and control applications, including:
- Machine control and visualization
- Data acquisition and processing
- Human-Machine Interface (HMI) systems
- Process control and monitoring
- Industrial communication gateways
- Manufacturing execution systems (MES)
- Distributed control systems (DCS) components
Technical Specifications
| Brand |
Siemens |
| Manufacturer |
Siemens |
| Range |
Simatic Box PC |
| Subrange |
IPC627C |
| Type of Product |
PC box |
| PLM Product Phase |
Phase-Out |
| Processor |
Intel Core i3-330E (2C/4T, 2.13 GHz, HT, VT, 3 MB Cache) |
| Graphics |
HD Graphic Onboard |
| Ethernet Ports |
2x 10/100/1000 Mbit/s RJ45 |
| USB Ports |
4x USB V2.0 (High Current) |
| Serial Port |
1x (COM 1) |
| RAID Controller |
Onboard |
| CompactFlash Drive |
No. 1 on front |
| Monitoring |
Watchdog, Temperature/Fan Monitoring |
| PROFIBUS/MPI |
CP 5611-A2-compatible |
| Buffered RAM |
2 MB |
| System Memory |
1 GB DDR3 1066 DIMM |
| Power Supply |
24 V DC Industrial |
| PCI Slots |
2x Free |
| RAID Configuration |
RAID1 |
| Storage Drives |
2x 320 GB SATA (2.5") |
| Optical Drive |
DVD +/-RW |
| Operating System |
Windows XP Professional SP3 MUI (DE, EN, FR, ES, IT) |
| Package Dimensions (Calculated) |
28.00 x 33.00 x 31.00 cm |
| Shipping Weight |
6.45 kg |
| Commodity Code |
85371091 |
Connections / Interfaces
-
Ethernet: 2x RJ45 ports (10/100/1000 Mbit/s)
-
USB: 4x USB V2.0 ports (High Current)
-
Serial: 1x COM 1 port
-
PROFIBUS/MPI: CP 5611-A2-compatible interface
-
CompactFlash: 1x Front-accessible slot
-
Optical Drive: DVD +/-RW
Installation Guidelines
-
Power De-energization: Before installation, ensure that all power to the installation site is de-energized and secured against accidental re-energization.
-
Mounting: Mount the Box PC securely in a suitable industrial enclosure or control cabinet, ensuring adequate ventilation for heat dissipation.
-
Power Connection: Connect the 24 V DC industrial power supply to the designated terminals, observing correct polarity. Ensure the power supply meets the specified voltage and current requirements.
-
Ethernet Connections: Connect industrial Ethernet cables to the RJ45 ports for network integration. Use shielded cables in electrically noisy environments.
-
USB and Serial Connections: Connect peripheral devices to the USB V2.0 ports and serial devices to the COM 1 port as required by the application.
-
PROFIBUS/MPI Connection: If utilizing PROFIBUS/MPI, connect the appropriate cable to the CP 5611-A2-compatible interface.
-
Grounding: Ensure proper grounding of the Box PC and the control cabinet to minimize electromagnetic interference and ensure operational safety.
-
Environmental Considerations: Verify that the operating environment's temperature, humidity, and vibration levels are within the permissible ranges for industrial PC equipment.
-
Initial Power-Up: After all connections are secured, re-energize the power supply and monitor the system for proper boot-up and operation.