Siemens

Siemens 6ES7647-6CE16-1BA0 SIMATIC IPC627C Box PC

SKU 6ES7647-6CE16-1BA0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7647-6CE16-1BA0

  • Country of origin:Germany

  • Product Type: Industrial Box PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 6450g

  • Dimensions: 28.00 x 33.00 x 31.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7647-6CE16-1BA0 is a SIMATIC IPC627C series Box PC designed for demanding industrial applications. This unit is powered by an Intel Core i3-330E processor and features integrated HD graphics. Connectivity is provided through dual Gigabit Ethernet ports, four high-current USB 2.0 ports, and a serial COM port. For system reliability, it includes an onboard RAID controller, watchdog timer, and active temperature and fan monitoring. A front-accessible CompactFlash drive slot allows for easy media access.

Features

  • Processor: Intel Core i3-330E (2 Cores / 4 Threads, 2.13 GHz)
  • Graphics: Integrated HD Graphics Onboard
  • Ethernet: Dual 10/100/1000 Mbit/s RJ45 Ports
  • USB: Four High-Current USB 2.0 Ports
  • Storage: Onboard RAID Controller
  • System Integrity: Watchdog Timer, Temperature and Fan Monitoring
  • Removable Media: Front-mounted CompactFlash Drive Slot

Applications

  • Process Visualization and HMI Server
  • Industrial Data Logging and Gateway
  • Machine-Level Control and Automation Tasks
  • Quality Assurance and Inspection Systems

Technical Specifications

Specification Value
Manufacturer Siemens
Part Number 6ES7647-6CE16-1BA0
Product Series SIMATIC IPC627C
Product Type Box PC
Processor Intel Core i3-330E (2 Cores, 4 Threads, 2.13 GHz)
Ethernet Ports 2 x 10/100/1000 Mbit/s Ethernet RJ45
USB Ports 4 x USB 2.0 (High Current)
Serial Port 1 x COM1
Product Lifecycle Status Phase-Out
Country of Origin Not specified in source data
Shipping Weight 6.45 kg
Package Dimensions (Calculated) 28.00 x 33.00 x 31.00 cm

Installation Guidelines

CRITICAL WARNING: This equipment contains components sensitive to electrostatic discharge (ESD). Use proper ESD protection, including wrist straps and grounded mats, during handling and installation to prevent permanent damage.
  1. 1 Ensure the control cabinet or mounting location is de-energized and locked out according to site safety procedures before beginning installation.
  2. 2 Verify the mounting orientation allows for unobstructed airflow to the unit's ventilation openings. Inadequate cooling can lead to overheating and system failure.
  3. 3 Securely fasten the Box PC chassis to the mounting plate or DIN rail adapter using the specified hardware and torque values.
  4. 4 Connect the chassis to the panel's protective earth (PE) busbar using a low-impedance conductor. This is critical for both safety and noise immunity.
  5. 5 Connect all required communication and I/O cables (Ethernet, USB, Serial). Ensure cables are properly routed and secured to prevent strain on the connectors.
  6. 6 Connect the main power supply to the unit. Double-check that the supply voltage matches the rating specified on the device label.
  7. 7 After a final inspection of all connections, remove the lockout/tagout and re-energize the cabinet to commission the system.

FAQ

What processor is installed in the 6ES7647-6CE16-1BA0?

This SIMATIC Box PC is equipped with an Intel Core i3-330E processor, which has 2 cores, 4 threads, and a clock speed of 2.13 GHz.

How many Ethernet ports does this industrial PC have?

The unit features two 10/100/1000 Mbit/s Gigabit Ethernet RJ45 ports for high-speed network communication.

Does the IPC627C support RAID configurations?

Yes, this model includes an onboard RAID controller to support redundant storage configurations for improved data reliability.

What is the product lifecycle status of this model?

According to the manufacturer, the 6ES7647-6CE16-1BA0 is in the 'Phase-Out' stage of its product lifecycle.

What system monitoring features are built-in?

The PC includes an integrated watchdog timer for system supervision, as well as active monitoring for internal temperature and fan status to ensure operational stability.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.