Siemens

Siemens 6ES7647-6CH16-0HX2 SIMATIC IPC627C Industrial Box PC

SKU 6ES7647-6CH16-0HX2

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7647-6CH16-0HX2

  • Country of origin:Germany

  • Product Type: Industrial Box PC

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 6350g

  • Dimensions: 80.0 x 15.0 x 12.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This Siemens 6ES7647-6CH16-0HX2 is a SIMATIC IPC627C series industrial box PC, engineered for robust performance in demanding automation and control applications. It is powered by an Intel Core i7-610E processor and equipped with 2 GB of DDR3 RAM for reliable multitasking. Data integrity is enhanced by an onboard RAID controller managing a RAID1 configuration of two 320 GB SATA drives. The unit operates on a 24 V DC industrial power supply and features integrated system monitoring functions, including a watchdog timer and temperature/fan monitoring, to ensure high availability and system stability.

Features

  • Equipped with an Intel Core i7-610E Processor (2.53 GHz, 2 Cores, 4 Threads)
  • 2 GB DDR3 1066 DIMM system memory
  • RAID1 configuration with two 320 GB SATA (2.5-inch) hard drives
  • Dual Gigabit Ethernet ports (10/100/1000 Mbit/s) for network connectivity
  • Integrated PROFIBUS/MPI interface (CP 5611-A2 compatible)
  • Powered by a 24 V DC industrial power supply
  • Onboard system monitoring for watchdog, temperature, and fan status
  • Includes a DVD+/-RW optical drive and a front-accessible CompactFlash slot
  • Four high-current USB 2.0 ports and one serial COM1 port

Applications

  • Process control and visualization systems
  • Data acquisition, logging, and analysis
  • Human-Machine Interface (HMI) server applications
  • Manufacturing Execution System (MES) terminals
  • Industrial automation gateways and communication nodes

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC IPC627C
Processor Intel Core i7-610E (2 Cores, 4 Threads, 2.53 GHz, 4 MB Cache)
Memory (RAM) 2 GB DDR3 1066 DIMM
Buffered Memory 2 MB buffered SRAM
Internal Storage 2 x 320 GB SATA (2.5") in RAID1 configuration
Optical Drive DVD+/-RW
Removable Media Front CompactFlash Drive Slot
Graphics Onboard HD Graphics
Ethernet Interface 2 x RJ45 (10/100/1000 Mbit/s)
Fieldbus Interface PROFIBUS/MPI (CP 5611-A2 compatible)
Serial Interface 1 x COM1
USB Interface 4 x USB 2.0 (High Current)
Expansion Slots 2 x PCI
Power Supply 24 V DC
System Monitoring Watchdog, Temperature, Fan
Operating System Not included
Included Software SIMATIC IPC Image & Partition Creator V3.4
PLM Status Phase-Out
Shipping Weight 6.35 kg
Package Dimensions (Calculated) 80.0 x 15.0 x 12.0 cm
Country of Origin Germany (Estimate)

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTRIC SHOCK AND EQUIPMENT DAMAGE

All installation and maintenance procedures must be performed by qualified personnel only. Disconnect and lock out all power sources before accessing terminals or internal components. Failure to comply can result in severe injury, death, or equipment damage. Always observe electrostatic discharge (ESD) precautions when handling the device.

  1. 1 De-energize System: Before installation, completely de-energize the control cabinet or mounting location. Use a multimeter to verify zero energy state and apply appropriate lockout/tagout (LOTO) procedures.
  2. 2 Verify Mounting Location: Ensure the selected mounting surface is mechanically sound and provides adequate clearance around the PC chassis for ventilation and cable access. Do not block fan inlets or outlets.
  3. 3 Secure the Chassis: Mount the IPC securely to the panel or enclosure using all provided mounting points and appropriate hardware. Verify the unit is level and stable.
  4. 4 Connect Power Supply: Connect the 24 V DC power source to the IPC's power input terminals. Strictly observe correct polarity (+/-) to prevent damage. Use appropriately sized conductors for the load.
  5. 5 Establish Ground Connection: Connect the chassis ground terminal to the main system protective earth (PE) bus bar using a low-impedance conductor. A reliable ground connection is critical for safety and noise immunity.
  6. 6 Connect I/O and Peripherals: Connect Ethernet, PROFIBUS/MPI, USB, and serial cables as required by the application. Ensure all connectors are fully seated and secured.
  7. 7 Final Checks and Power-Up: Double-check all wiring and connections. Remove all tools and foreign objects from the enclosure. Remove LOTO devices and re-energize the system according to site procedures.

FAQ

What processor is used in this IPC?

It is equipped with an Intel Core i7-610E processor, featuring 2 cores, 4 threads, and a 2.53 GHz clock speed.

Does this unit come with an operating system?

No, this model is supplied without a pre-installed operating system. It includes the SIMATIC IPC Image & Partition Creator V3.4 software.

What are the primary communication interfaces?

It includes two Gigabit Ethernet ports, one PROFIBUS/MPI interface, four high-current USB 2.0 ports, and one serial COM1 port.

What is the power supply requirement for this industrial PC?

The IPC requires a 24 V DC industrial power supply.

What type of storage configuration does this model have?

This unit is configured with two 320 GB SATA hard drives operating in a RAID1 (mirroring) configuration for data redundancy.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...