Description
This is a Siemens 6ES7647-6ME05-0WX0 SIMATIC Box PC 840 V2, a robust industrial computer designed for demanding automation environments. It is equipped with a Pentium 4 M 2.2 GHz processor, 128 MB DDR SDRAM, and a 24V DC industrial power supply. This specific configuration includes a floppy disk drive (FDD) but is supplied without a hard disk drive (HDD), DVD-ROM, or operating system. Integrated features include onboard AGP graphics with shared memory, 10/100 Mbit/s Ethernet, and two high-current USB ports. The system also incorporates a watchdog timer and temperature monitoring for enhanced reliability and operational stability.
Features
- Processor: Pentium 4 M 2.2 GHz with 400 MHz FSB and 512 KB SLC
- Memory: 128 MB DDR SDRAM
- Graphics: Onboard AGP with 8/16/32 MB shared memory
- Networking: Integrated 10/100 Mbit/s Ethernet RJ45 port
- I/O Ports: 2x High-Current USB
- Expansion Slots: 2x PCI, 2x ISA/PCI (shared), 1x ISA
- Power Supply: 24V DC Industrial Power Supply
- System Monitoring: Integrated watchdog timer and temperature monitoring
- Storage: Includes Floppy Disk Drive (FDD); no HDD or DVD-ROM
Applications
- Human-Machine Interface (HMI) visualization stations
- Process control and data acquisition systems
- Machine-level data logging and analysis
- Industrial gateways and communication servers
- Factory automation and assembly line control
Technical Specifications
| Specification |
Value |
| Brand |
Siemens |
| Model |
6ES7647-6ME05-0WX0 |
| Series |
SIMATIC Box PC 840 V2 |
| Product Type |
Industrial PC |
| Processor |
Pentium 4 M 2.2 GHz |
| Front Side Bus (FSB) |
400 MHz |
| Second Level Cache (SLC) |
512 KB |
| RAM |
128 MB DDR SDRAM |
| Graphics |
Onboard AGP, 8/16/32 MB Shared Memory |
| Ethernet |
1x RJ45, 10/100 Mbit/s |
| USB Ports |
2x High Current USB |
| Expansion Slots |
2 PCI, 2 ISA/PCI, 1 ISA |
| Input Voltage |
24V DC |
| Product Lifecycle Status |
Obsolete |
| Shipping Weight |
11.50 kg |
| Package Dimensions (Calculated) |
51.00 x 62.50 x 23.00 cm |
| Country of Origin |
Germany (Estimated) |
| Manufacturer |
Siemens |
Installation Guidelines
CRITICAL WARNING: RISK OF ELECTRIC SHOCK
Installation must be performed by qualified personnel only. Disconnect all power sources and follow Lockout/Tagout (LOTO) procedures before accessing or installing this equipment. Failure to de-energize the system can result in severe injury or death.
-
1
Ensure the mounting location provides adequate ventilation and meets environmental specifications. Verify clearances for cabling and future maintenance access.
-
2
Securely mount the Box PC chassis to the panel or mounting surface using all provided mounting points. Ensure the unit is level and stable.
-
3
Connect a low-impedance protective earth (PE) conductor to the designated chassis grounding terminal. This is a critical safety connection.
-
4
Connect the 24V DC power supply to the correct input terminals, observing proper polarity. Use appropriately sized conductors for the load.
-
5
Connect all required peripherals, including Ethernet, USB devices, and video displays. Route cables to prevent strain and interference.
-
6
After verifying all connections, remove LOTO devices and re-apply power to the control panel. Proceed with operating system installation and software configuration.