Siemens

Siemens 6ES7647-7BG20-2XX0 SIMATIC IPC427C Microbox PC

SKU 6ES7647-7BG20-2XX0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7647-7BG20-2XX0

  • Country of origin:Germany

  • Product Type: Industrial PC

  • Barcode: 85371099

  • Payment: T/T, Western Union

  • Weight: 3250g

  • Dimensions: 76.00 x 22.00 x 5.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

This device is a Siemens 6ES7647-7BG20-2XX0 SIMATIC IPC427C, a compact and robust Microbox PC designed for industrial automation applications. It is equipped with an Intel Core 2 Solo 1.2 GHz processor, featuring an 800 MHz FSB and 3 MB SLC for reliable performance. This configuration includes 1 GB of DDR3 1066 SODIMM memory and a user-accessible, replaceable 2 GB CompactFlash card for storage. For network connectivity, it features an integrated 3-port PROFINET interface. This unit is supplied without a pre-installed operating system, allowing for custom software deployment.

Features

  • Processor: Intel Core 2 Solo at 1.2 GHz
  • Memory: 1 GB DDR3 1066 SODIMM
  • Storage: 2 GB replaceable CompactFlash card
  • Industrial Networking: Integrated 3-port PROFINET interface
  • Form Factor: Compact, fanless Microbox design
  • Operating System: Not included

Applications

  • Machine-level data acquisition and processing
  • Human-Machine Interface (HMI) and SCADA applications
  • Communication gateway between different fieldbus networks
  • Process control and monitoring in manufacturing environments
  • Embedded control systems requiring PC-based architecture

Technical Specifications

Specification Value
Manufacturer Siemens
Part Number 6ES7647-7BG20-2XX0
Product Series SIMATIC IPC427C
Product Type Microbox PC
Processor Intel Core 2 Solo 1.2 GHz, 800 MHz FSB, 3 MB SLC
Memory Configuration 1 GByte DDR3 1066, SODIMM
Hardware Extension Without expansions
Accessible Drive 2 GB CompactFlash (Replaceable)
Internal Drive None
Operating System None
Integrated Interfaces PROFINET (3 Ports)
Product Lifecycle Status Phase-Out
Shipping Weight 3.25 kg
Package Dimensions 76.00 x 22.00 x 5.00 cm
Commodity Code 85371099
Export Control (ECCN) N
Country of Origin (Estimated) Germany

Installation Guidelines

CRITICAL WARNING: Installation must be performed by qualified personnel only. Failure to adhere to safety protocols can result in equipment damage, system failure, or serious injury. Always de-energize equipment and follow lock-out/tag-out (LOTO) procedures before commencing work.
  1. 1 Site Preparation: Ensure the mounting location inside the control cabinet is clean, dry, and free from excessive vibration. Verify adequate clearance around the unit for heat dissipation as per the device's mounting orientation requirements.
  2. 2 Mounting: Securely fasten the IPC427C to a standard DIN rail or directly to the panel backplane using the appropriate mounting hardware. Ensure the unit is mechanically stable.
  3. 3 Grounding: Connect a low-impedance protective earth (PE) conductor to the designated grounding terminal on the IPC chassis. Proper grounding is essential for noise immunity and safety.
  4. 4 Power Connection: Connect the specified DC power supply to the power input terminals. Verify correct voltage and polarity before applying power. Use appropriately sized conductors and ensure connections are torqued correctly.
  5. 5 Interface Cabling: Connect PROFINET and any other required interface cables (e.g., USB, display). Ensure all cables are properly shielded and routed away from high-voltage lines to minimize electrical noise interference.
  6. 6 System Commissioning: After verifying all connections, remove the LOTO and apply power to the cabinet. Proceed with operating system installation and application software configuration.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.