Siemens

Siemens 6ES7647-7BK40-0DB0 SIMATIC IPC427C Microbox PC

SKU 6ES7647-7BK40-0DB0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7647-7BK40-0DB0

  • Country of origin:Germany

  • Product Type: PC Microbox

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 3200g

  • Dimensions: 76.00 x 22.00 x 5.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7647-7BK40-0DB0 is a SIMATIC IPC427C Microbox PC designed for industrial automation applications. This compact industrial PC features a Core 2 Duo 1.2 GHz processor with an 800 MHz Front Side Bus (FSB) and 3 MB Second Level Cache (SLC). It is equipped with 4 GB of DDR3 1066 SODIMM memory and a 50 GB Solid-State-Drive (SATA) with high endurance, which is replaceable. The unit comes with Windows XP Professional Multi-Language pre-installed and includes a PROFIBUS DP 12 interface for communication within industrial control systems.

Features

  • Core 2 Duo 1.2 GHz Processor with 800 MHz FSB and 3 MB SLC
  • 4 GB DDR3 1066 SODIMM Memory Configuration
  • 50 GB Solid-State-Drive (SATA, High Endurance)
  • PROFIBUS DP 12 Communication Interface
  • Pre-installed Windows XP Professional Multi-Language Operating System
  • Replaceable Mass Storage Drive

Applications

The SIMATIC IPC427C Microbox PC is suitable for various industrial applications requiring a robust and compact computing solution, including:
  • Machine control and visualization
  • Data acquisition and processing
  • Distributed control systems (DCS)
  • Human Machine Interface (HMI) tasks
  • Embedded control systems

Technical Specifications

Brand Siemens
Manufacturer Siemens
Range Simatic Box PC
Subrange IPC427C
Product Type PC Microbox
Processor Core 2 Duo 1.2 GHz
Front Side Bus (FSB) 800 MHz
Second Level Cache (SLC) 3 MB
Memory Configuration 4 GB DDR3 1066, SODIMM
Hardware Extension Without expansions
Drive Type Solid-State-Drive SATA (high endurance)
Drive Capacity 50 GB
Operating System Windows XP Prof. Multi-Language (pre-installed)
Communication Interface PROFIBUS DP 12
Product Phase Phase-Out
Package Dimensions 76.00 x 22.00 x 5.00 cm
Shipping Weight 3.20 kg
Commodity Code 85371091
Export Control Regulations (ECCN) N

Installation Guidelines

  1. De-energize System: Ensure all power to the installation area and connected equipment is disconnected and locked out before beginning any work.
  2. Mounting: Securely mount the Microbox PC in a suitable industrial enclosure or control cabinet, ensuring adequate ventilation and clearance for cable routing and heat dissipation.
  3. Power Connection: Connect the appropriate power supply according to the system's electrical requirements. Verify correct polarity and grounding.
  4. PROFIBUS Connection: Connect the PROFIBUS DP 12 cable to the designated port, ensuring proper termination and shielding for reliable communication.
  5. Peripheral Connections: Connect any necessary peripherals such as display, keyboard, and mouse to the available ports.
  6. Grounding: Ensure the Microbox PC and its enclosure are properly grounded to minimize electrical noise and ensure safety.
  7. Cable Routing: Route all cables to prevent strain, interference, and damage, separating power and signal cables where possible.
  8. Environmental Considerations: Operate the device within its specified temperature and humidity ranges to ensure optimal performance and longevity.
  9. Power Up: After all connections are secure and verified, restore power to the system and observe for proper boot-up and operation.

FAQ

What is the processor configuration of the 6ES7647-7BK40-0DB0?

The unit features a Core 2 Duo 1.2 GHz processor with an 800 MHz FSB and 3 MB SLC.

What operating system is pre-installed on this Microbox PC?

It comes with Windows XP Professional Multi-Language pre-installed on the internal drive.

What type and capacity of storage does the IPC427C include?

The IPC427C is equipped with a 50 GB Solid-State-Drive (SATA) designed for high endurance, which is also replaceable.

Does this Microbox PC support industrial communication protocols?

Yes, it includes a PROFIBUS DP 12 interface for industrial communication.

What is the memory configuration of the device?

The device has 4 GB of DDR3 1066 SODIMM memory.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.