Siemens

Siemens 6ES7675-1DJ30-1AA0 SIMATIC IPC427C PC Microbox

SKU 6ES7675-1DJ30-1AA0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7675-1DJ30-1AA0

  • Country of origin:Germany

  • Product Type: PC Microbox

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 3g

  • Dimensions: 39.50 x 30.00 x 17.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7675-1DJ30-1AA0 is a SIMATIC IPC427C PC Microbox, designed as a compact industrial personal computer bundle. This unit features an Intel Core2Duo 1.2 GHz processor, 2 GByte RAM, and integrated communication interfaces including 2 x 10/100 Mbit/s Ethernet RJ45 ports, 4 x USB ports, and 1 x serial (COM1) port. It also includes a slot for a Compact Flash drive, though the CF card and software are not included with the bundle. This PC microbox is suitable for various industrial automation and control applications where a robust, embedded computing solution is required.

Features

  • Intel Core2Duo 1.2 GHz Processor
  • 2 GByte RAM
  • 2 x 10/100 Mbit/s Ethernet RJ45 Interfaces
  • 4 x USB Ports
  • 1 x Serial (COM1) Port
  • 1 x Slot for Compact Flash Drive (CF card and software not included)

Applications

The Siemens SIMATIC IPC427C PC Microbox is typically deployed in industrial environments for tasks such as:
  • Machine control and visualization
  • Data acquisition and processing
  • Embedded control systems
  • Distributed automation solutions
  • Gateway functions in industrial networks

Technical Specifications

Parameter Value
Manufacturer Siemens
Range Simatic Box PC
Subrange IPC427C
Product Type PC Microbox
PLM Product Phase Phase-Out
Processor Intel Core2Duo 1.2 GHz
RAM 2 GByte
Package Dimensions (Calculated) 39.50 x 30.00 x 17.00 cm
Shipping Weight 3.00 kg
Commodity Code 85371091

Connections / Interfaces

Interface Type Quantity / Specification
Ethernet 2 x RJ45 (10/100 Mbit/s)
USB 4 x
Serial 1 x (COM1)
Expansion Slot 1 x Compact Flash Drive Slot

Installation Guidelines

  1. De-energize System: Ensure all power to the installation area and associated equipment is disconnected before beginning installation.
  2. Mounting: Securely mount the PC Microbox in a suitable industrial enclosure or control cabinet, typically using DIN rail or panel mounting hardware. Ensure adequate space for ventilation and cable routing.
  3. Grounding: Establish a proper protective earth (PE) connection to the device's designated grounding terminal to ensure electrical safety and minimize electromagnetic interference.
  4. Power Connection: Connect the industrial PC to a stable and appropriate power supply, observing correct voltage and polarity.
  5. Interface Connections: Connect Ethernet cables to the RJ45 ports for network communication. Connect USB devices and serial communication cables as required for the application.
  6. Cable Routing: Route all cables to prevent strain, interference, and damage. Separate power cables from signal cables where possible.
  7. Environmental Considerations: Ensure the operating environment adheres to the specified temperature, humidity, and vibration limits for industrial PCs to maintain optimal performance and longevity.
  8. Re-energize and Test: After all connections are secure and verified, re-apply power to the system and perform functional tests to confirm correct operation.

FAQ

What is the primary function of the SIMATIC IPC427C PC Microbox?

It serves as a compact, robust industrial personal computer for embedded control, data acquisition, and visualization tasks in automation environments.

What type of processor does this unit utilize?

The IPC427C features an Intel Core2Duo processor clocked at 1.2 GHz.

Does this bundle include a Compact Flash card or software?

No, the bundle includes a slot for a Compact Flash drive, but the CF card itself and any operating system or application software are not included.

What communication interfaces are available on this PC Microbox?

It provides two 10/100 Mbit/s Ethernet RJ45 ports, four USB ports, and one serial (COM1) port for various industrial communication needs.

What are the physical dimensions of the package?

The package dimensions are 39.50 cm (length) x 30.00 cm (width) x 17.00 cm (height).

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.