Description
The Siemens 6ES7710-0DA10-0CA1 is a SIMATIC Field PG programming device designed for mobile use in industrial automation environments. This unit features a Celeron 650 MHz processor with 128 KB of 2nd level cache, 128 MB of SDRAM, and a 10.2 GByte EIDE hard disk drive. It includes both a CD-ROM drive and a SuperDisk LS 240 drive for versatile data handling. The Field PG comes pre-installed with Windows ME (French version) and essential Siemens STEP software, including STEP 7 Professional, STEP 5, and STEP 7 MicroWIN, with an installation date of August 2001. It serves as a dedicated tool for programming, configuring, and diagnosing SIMATIC automation systems.
Features
- Celeron 650 MHz Processor with 128 KB 2nd Level Cache
- 128 MB SDRAM (1x128 MB)
- 10.2 GByte EIDE Hard Disk Drive
- Integrated CD-ROM Drive
- Integrated SuperDisk LS 240 Drive
- Pre-installed Windows ME (French) Operating System
- Pre-installed STEP 7 Professional, STEP 5, and STEP 7 MicroWIN Software (08/2001)
- Designed for mobile industrial programming and diagnostics
Applications
- Programming and configuration of SIMATIC S5 and S7 Programmable Logic Controllers (PLCs).
- On-site diagnostics, troubleshooting, and maintenance of industrial automation systems.
- Mobile engineering workstation for automation software development and deployment.
Technical Specifications
| Parameter |
Value |
| Brand |
Siemens |
| Manufacturer |
Siemens |
| Range |
SIMATIC Field PG |
| Subrange |
Field PG |
| Product Type |
Pentium 3 |
| Processor |
Celeron 650 MHz |
| Cache |
128 KB 2nd Level Cache |
| RAM |
128 MB SDRAM (1x128 MB) |
| Hard Disk Drive |
10.2 GByte EIDE |
| Optical Drive |
CD-ROM Drive |
| Floppy Drive |
SuperDisk LS 240 Drive |
| Operating System |
Windows ME French |
| Pre-installed Software |
STEP 7 Professional, STEP 5, STEP 7 MicroWIN (Installed 08/2001) |
| Product Phase |
Phase-Out |
| Package Dimensions |
29.00 x 25.00 x 25.00 cm |
| Shipping Weight |
4.00 kg |
| Commodity Code |
84713000 |
| Export Control Regulations (ECCN) |
N |
Installation Guidelines
-
Power Connection: Connect the Field PG to a stable and grounded power source using the appropriate power adapter. Ensure the voltage and frequency match the device's requirements.
-
Peripheral Setup: Connect any necessary peripherals such as a mouse, external keyboard, or external monitor if required for the task.
-
Communication Interface: Utilize the appropriate communication cables (e.g., MPI/DP cable, Ethernet cable) to connect the Field PG to the target SIMATIC PLC or automation network.
-
Environmental Considerations: Operate the Field PG within its specified environmental limits for temperature and humidity. Avoid exposure to excessive dust, moisture, or strong electromagnetic interference.
-
Software Initialization: Upon initial boot, verify that the Windows ME operating system and pre-installed STEP software are functioning correctly. Perform any necessary driver updates or software configurations as per the specific application requirements.
-
Safety Precautions: Always ensure that the target automation system is in a safe state (e.g., de-energized or in a controlled stop) before connecting the Field PG for programming or diagnostics, especially when making physical connections.