Siemens

Siemens 6ES7715-1BB20-0AA3 SIMATIC Field PG M3 Industrial Programming Device

SKU 6ES7715-1BB20-0AA3

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7715-1BB20-0AA3

  • Country of origin:Germany

  • Product Type: Industrial Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3200g

  • Dimensions: 38.1 x 27.9 x 55.9 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7715-1BB20-0AA3 is a SIMATIC Field PG M3, a robust industrial notebook engineered for automation programming, commissioning, and maintenance tasks in demanding production environments. This Premium configuration is powered by an Intel Core i5-520M processor running at 2.4 GHz and is equipped with 3 GB of DDR3 RAM for reliable performance. It features a large 500 GB SATA hard drive for project storage and a high-resolution 15.6-inch Full HD display (1920x1080) for clear visualization of complex engineering software. This model is specifically supplied without S5 interface or S5-PROMMER hardware, focusing on modern automation platforms.

Features

  • Processor: Intel Core i5-520M (2.4 GHz)
  • Memory: 3 GB DDR3 RAM (1x 1 GB, 1x 2 GB)
  • Storage: 500 GB SATA Hard Disk Drive (HDD)
  • Display: 15.6-inch Full HD with 1920x1080 resolution
  • Optical Drive: DL Multi-Standard DVD RW
  • Keyboard: QWERTY layout with German characters
  • Operating System: Windows XP Professional (English MUI)
  • Included Software: Trial licenses for STEP 7 Professional and WinCC flexible Advanced (Version 02/2012)
  • Power: Includes line cables for multiple European countries

Applications

  • PLC and DCS programming, configuration, and diagnostics
  • HMI and SCADA application development
  • On-site system commissioning and startup
  • Field maintenance and troubleshooting of automated systems
  • Mobile engineering workstation for industrial environments

Technical Specifications

Specification Value
Brand Siemens
Product Series SIMATIC Field PG M3
Configuration Premium
Processor Intel Core i5-520M
Processor Clock Speed 2.4 GHz
Memory (RAM) 3 GB DDR3 (1x 1 GB, 1x 2 GB)
Storage 500 GB SATA HDD
Display Size 15.6 inch
Display Resolution 1920 x 1080 (Full HD)
Optical Drive DL Multi-Standard DVD RW
Keyboard QWERTY (& German)
S5 Interface Not included
S5 EPROM Programmer Not included
Operating System Windows XP Professional English MUI (with DE/FR/SP/IT images)
Bundled Software Trial License for STEP 7 Professional, WinCC flexible Advanced
Software Version 02/2012
Approvals CE (Europe)
Included Line Cables DE, FR, NL, ES, BE, AT, SE, FI, CH, IT
Product Lifecycle Status Obsolete
Export Control (ECCN) 5D002
Commodity Code 84713000
Shipping Weight 3.20 kg
Package Dimensions (Calculated) 38.1 x 27.9 x 55.9 cm
Country of Origin Germany (Estimate)
Manufacturer Siemens

Installation Guidelines

CRITICAL WARNING: This equipment is intended for use by qualified personnel only. Failure to observe safety precautions can result in equipment damage or severe personal injury. Always disconnect from power sources before performing any service.
  1. 1 Initial Inspection: Before use, carefully inspect the Field PG housing, screen, keyboard, and power supply for any signs of shipping damage. Do not operate if damage is apparent.
  2. 2 Power Connection: Select the appropriate line cable for your region from the supplied set. Connect the power adapter securely to the Field PG and then to a properly grounded mains outlet. Use of a surge protector is recommended in industrial settings.
  3. 3 System Startup: Power on the device and allow the Windows XP operating system to boot completely. Verify functionality of the display, keyboard, and trackpad before connecting to any automation hardware.
  4. 4 Network and Device Connection: Connect to automation networks or PLCs using the appropriate interface cables (e.g., Ethernet, PROFIBUS adapter). Ensure all connections are secure before initiating communication.
  5. 5 Operating Environment: Operate the Field PG on a stable, level surface. Avoid exposure to excessive moisture, dust, vibration, or extreme temperatures to ensure long-term reliability.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.