Siemens

Siemens 6ES7716-1BA10-0EA3 SIMATIC Field PG M4 Industrial Programming Device

SKU 6ES7716-1BA10-0EA3

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7716-1BA10-0EA3

  • Country of origin:Germany

  • Product Type: Industrial Programming Devices

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Dimensions: 39.5 x 30.0 x 17.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7716-1BA10-0EA3 is a SIMATIC Field PG M4 Premium, a ruggedized portable computer designed for automation engineering tasks in industrial environments. This device is equipped with an Intel Core i5-3320M processor, 16 GB of RAM (2x 8GB), and a 1 TB HDD for ample performance and storage. It features a 15.6-inch Full HD display and comes with a dual-boot operating system configuration of Windows XP Professional and Windows 7 Ultimate. The unit includes trial licenses for key Siemens engineering software, providing a comprehensive platform for commissioning, servicing, and maintaining automation systems. This specific model is supplied without an S5 interface, S5 EPROM programmer, or MPI cable.

Features

  • Processor: Intel Core i5-3320M (2.6 GHz base, up to 3.3 GHz with Turbo Boost)
  • Memory: 16 GB RAM (2 x 8 GB modules)
  • Storage: 1 TB SATA Hard Disk Drive (HDD)
  • Display: 15.6-inch Full HD (1920 x 1080) screen
  • Optical Drive: DVD RW
  • Operating System: Dual-boot with Windows XP Professional SP3 and Windows 7 Ultimate SP1 (64-bit)
  • Keyboard: QWERTY layout (with German characters)
  • Pre-installed Software: Trial licenses for STEP 7 Professional Combo (V13/2010), WinCC Advanced Combo (V13/WinCC flexible 2008), and STEP 7 Micro/WIN V4.0

Applications

  • PLC and HMI programming and configuration
  • Commissioning of industrial automation systems
  • On-site diagnostics and troubleshooting
  • System maintenance and service
  • Mobile engineering workstation for plant floor environments

Technical Specifications

Hardware Configuration
Processor Intel Core i5-3320M (3M Cache, 2.6 GHz, up to 3.3 GHz with Turbo Boost Technology)
Memory (RAM) 16 GB (2 x 8 GB)
Storage 1 TB HDD SATA
Graphics Intel HD Graphics 4000
Display 15.6-inch Full HD (1920 x 1080)
Optical Drive DVD RW
Keyboard QWERTY (& German)
Interfaces Without S5 Interface, Without S5-EPROMMER
Software
Operating System Dual Boot: Windows XP Professional SP3 / Windows 7 Ultimate SP1 (64-bit)
Included Licenses Trial License for STEP 7 Professional Combo (V13/2010), WinCC Advanced Combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0
Software Version V13.0.0.0
General & Logistical Information
Manufacturer Siemens
Product Series SIMATIC Field PG M4
Product Lifecycle Status Phase-Out
Included Power Cable Line cable for DE, FR, NL, SP, BEL, OES, SWD, FIN
Country of Origin Unknown
Package Dimensions (Calculated) 39.50 x 30.00 x 17.00 cm
Shipping Weight 3.50 kg
Commodity Code 84713000

Installation Guidelines

CRITICAL WARNING: This device is sensitive electronic equipment. Always handle with care and use appropriate electrostatic discharge (ESD) protection. Ensure the device is powered down correctly through the operating system before disconnecting power to prevent data corruption.
  1. 1 Initial Setup: Unpack the Field PG and all accessories. Connect the provided power cable to the device and a properly grounded AC outlet. Do not use extension cords or power strips that are not surge-protected.
  2. 2 First Power-On: Press the power button to start the device. On the first boot, you may be prompted to select an operating system from the dual-boot menu. Follow any on-screen prompts for initial system configuration.
  3. 3 Software Activation: The pre-installed Siemens engineering software is provided with trial licenses. To use the full functionality, you must acquire and install permanent licenses through the appropriate Siemens channels.
  4. 4 Operating Environment: Use the Field PG in an environment free from excessive dust, moisture, and vibration. Ensure adequate ventilation around the device to prevent overheating, especially during computationally intensive tasks like compiling large projects.
  5. 5 Connecting to Automation Hardware: Use only Siemens-approved communication cables and adapters when connecting to PLCs, HMIs, or other industrial hardware. Ensure all devices are properly grounded before establishing a connection.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...