Siemens

Siemens 6ES7716-2CA10-0CA4 SIMATIC Field PG M4 Premium Plus Programming Device

SKU 6ES7716-2CA10-0CA4

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7716-2CA10-0CA4

  • Country of origin:Germany

  • Product Type: Industrial Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3200g

  • Dimensions: 39.50 x 30.00 x 17.00 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7716-2CA10-0CA4 is a SIMATIC Field PG M4 Premium Plus, an industrial programming device designed for robust automation engineering tasks. It features an Intel Core i7-35X0M processor with 4 MB cache, operating at 2.9 GHz and capable of reaching up to 3.6 GHz with Turbo BOOST technology. The device includes a DVD RW optical drive and an HD Graphic 4000 for display capabilities. For storage, it is equipped with a 300 GB SATA Solid State Drive (SSD). This model does not include an S5 interface or an S5-EPROMMER, and it is supplied without an MPI cable.

The Field PG M4 Premium Plus boasts a 15.6-inch Full HD display with a resolution of 1920 x 1080. It comes with a QWERTY keyboard (with German layout) and a line cable suitable for various European regions (DE, FR, NL, SP, BEL, OES, SWD, FIN). The operating system is Windows 7 Ultimate SP1, 64-bit, pre-installed with multi-language support (de/en/fr/es/it). It is configured with 16 GB of RAM (2x 8 GB). Please note that STEP 5 and STEP 7-Micro/WIN are not pre-installed, and STEP 5 is not executable in Windows 7. The device includes trial licenses for STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), and STEP 7 Micro/WIN V4.0. The pre-installed software version is V13.0.1.0.

Features

  • Intel Core i7-35X0M Processor (2.9 GHz, up to 3.6 GHz Turbo Boost)
  • 15.6-inch Full HD Display (1920 x 1080)
  • 300 GB SATA Solid State Drive (SSD)
  • 16 GB RAM (2x 8 GB)
  • DVD RW Optical Drive
  • HD Graphic 4000
  • Pre-installed Windows 7 Ultimate SP1, 64-bit (de/en/fr/es/it)
  • QWERTY keyboard with German layout
  • Includes line cable for DE, FR, NL, SP, BEL, OES, SWD, FIN
  • Trial licenses for STEP7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0
  • Without S5 interface or S5-EPROMMER
  • Without MPI cable

Applications

The Siemens SIMATIC Field PG M4 Premium Plus is suitable for a wide range of industrial automation applications, including:

  • Programming, configuration, and commissioning of SIMATIC PLCs and HMI systems.
  • On-site diagnostics and troubleshooting of automation equipment.
  • Maintenance and service tasks for industrial control systems.
  • Development and testing of automation projects in a field environment.
  • Data acquisition and analysis from connected industrial devices.

Technical Specifications

Attribute Value
Manufacturer Siemens
Brand Siemens
Range SIMATIC Field PG
Subrange Field PG M4
Product Type Premium Plus Programming Device
Processor Intel Core i7-35X0M
Processor Cache 4 MB
Processor Base Clock 2.9 GHz
Processor Turbo Boost Up to 3.6 GHz
RAM 16 GB (2x 8 GB)
Storage Type SATA Solid State Drive (SSD)
Storage Capacity 300 GB
Optical Drive DVD RW
Graphics HD Graphic 4000
Display Size 15.6 inches
Display Resolution Full HD (1920 x 1080)
Keyboard Layout QWERTY (with German layout)
Operating System Windows 7 Ultimate SP1, 64-bit (de/en/fr/es/it)
Pre-installed Software Version V13.0.1.0
S5 Interface Not included
S5-EPROMMER Not included
MPI Cable Not included
Product Phase Phase-Out
Package Dimensions (Calculated) 39.50 x 30.00 x 17.00 cm
Shipping Weight 3.20 kg
Commodity Code 84713000
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Environmental Considerations: Operate the Field PG within specified temperature and humidity ranges to ensure optimal performance and longevity. Avoid direct sunlight, excessive dust, and corrosive environments.
  2. Power Connection: Connect the Field PG to a stable power source using the provided line cable. Ensure the power outlet meets the device's electrical requirements.
  3. Initial Setup: Upon first use, follow the on-screen prompts for Windows 7 setup and any initial configuration required for the pre-installed software.
  4. Software Installation: While some trial licenses are included, specific full versions of engineering software (e.g., STEP 7, WinCC) may need to be installed separately based on project requirements.
  5. Peripheral Connections: Connect necessary peripherals such as external monitors, USB devices, or network cables to the appropriate ports.
  6. Data Backup: Regularly back up important project data and system configurations to an external storage device to prevent data loss.
  7. Security: Implement appropriate security measures, including strong passwords and antivirus software, to protect the device and sensitive project information.

FAQ

What is the primary purpose of the Siemens 6ES7716-2CA10-0CA4?

It is an industrial programming device, part of the SIMATIC Field PG M4 series, designed for programming, commissioning, and diagnostics of Siemens automation systems in field environments.

Does this Field PG M4 come with an S5 interface?

No, the 6ES7716-2CA10-0CA4 model is specified as being without an S5 interface and without an S5-EPROMMER.

What operating system is pre-installed on this device?

The device comes with Windows 7 Ultimate SP1, 64-bit, pre-installed with multi-language support (German, English, French, Spanish, Italian).

Are full versions of STEP 7 or WinCC included?

No, full versions of STEP 7 and WinCC are not pre-installed. The device includes trial licenses for STEP7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), and STEP 7 Micro/WIN V4.0.

What is the storage capacity and type?

It is equipped with a 300 GB SATA Solid State Drive (SSD).

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.