Description

The Siemens 6ES7716-2CA10-0EB4 is a SIMATIC Field PG M4 Premium Plus industrial programming device, designed for robust performance in automation engineering environments. This unit features an Intel Core I7-35X0M processor with 4 MB cache, operating at 2.9 GHz (up to 3.6 GHz with Turbo Boost technology). It includes a DVD RW optical drive, HD Graphic 4000, and a 300 GB SATA Solid-State Drive. The device is equipped with a 15.6-inch Full HD (1920x1080) display and a QWERTY (German) keyboard. It supports dual-boot functionality with pre-installed Windows XP Professional SP3 and Windows 7 Ultimate SP1 (64-bit), complemented by 2x 8GB RAM. This Field PG comes with essential software licenses, including STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), and STEP 7 Micro/WIN V4.0, along with an MPI cable. It does not include an S5 interface or S5-EPROMMER.

Features

  • Intel Core I7-35X0M Processor (2.9 GHz, up to 3.6 GHz Turbo Boost)
  • 4 MB Processor Cache
  • 15.6-inch Full HD (1920x1080) Display
  • 300 GB SATA Solid-State Drive (SSD)
  • HD Graphic 4000
  • DVD RW Optical Drive
  • Dual Boot Operating System: Windows XP Professional SP3 and Windows 7 Ultimate SP1 (64-bit)
  • 16 GB RAM (2x 8GB)
  • Pre-installed Software Licenses: STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0
  • Includes MPI Cable
  • QWERTY (German) Keyboard Layout
  • Line cable for DE, FR, NL, SP, BEL, OES, SWD, FIN
  • Software Version V13.0.1.0

Applications

The SIMATIC Field PG M4 Premium Plus is suitable for a range of industrial automation tasks, including:
  • Programming and configuration of Siemens SIMATIC PLCs and HMI systems.
  • On-site commissioning and diagnostics of automation equipment.
  • Development and testing of control programs.
  • Maintenance and troubleshooting of industrial control systems.

Technical Specifications

Attribute Value
Manufacturer Siemens
Range Simatic Field PG
Subrange Field PG M4
Type of Product Premium
Product Phase Phase-Out
Processor Intel Core I7-35X0M
Processor Speed 2.9 GHz (up to 3.6 GHz with Turbo Boost)
Processor Cache 4 MB
RAM 2x 8GB (16 GB total)
Storage 300 GB SATA Solid-State Drive
Graphics HD Graphic 4000
Optical Drive DVD RW
Display Size 15.6 inches
Display Resolution Full HD (1920x1080)
Keyboard Layout QWERTY (German)
Operating Systems Windows XP Professional SP3, Windows 7 Ultimate SP1 (64-bit)
Software Licenses Included STEP7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0
Software Version V13.0.1.0
S5 Interface Not included
S5-EPROMMER Not included
Package Dimensions (Calculated) 39.50 x 30.00 x 17.00 cm
Shipping Weight 3.50 kg
Commodity Code 84713000
Export Control Regulations (ECCN) N

Installation Guidelines

  1. Unpacking and Inspection: Carefully unpack the Field PG and inspect for any physical damage. Retain original packaging for potential future transport.
  2. Power Connection: Connect the provided line cable to the Field PG and a suitable power outlet. Ensure the power supply meets local electrical standards.
  3. Initial Setup: Power on the device. Follow the on-screen prompts for initial operating system configuration, if required.
  4. Software Installation/Configuration: Verify the pre-installed engineering software (STEP7, WinCC, Micro/WIN) is correctly configured. Install any necessary drivers or updates for specific automation hardware.
  5. Peripheral Connections: Connect the MPI cable or other required communication cables (e.g., Ethernet) to the Field PG and the target automation device.
  6. Environmental Considerations: Operate the Field PG within its specified environmental conditions to ensure optimal performance and longevity. Avoid extreme temperatures, humidity, and direct exposure to dust or corrosive agents.
  7. Data Backup: Regularly back up important project data and configurations to an external storage device to prevent data loss.

FAQ

What operating systems are pre-installed on the SIMATIC Field PG M4?

The device features a dual-boot configuration with Windows XP Professional SP3 and Windows 7 Ultimate SP1 (64-bit) pre-installed.

Which engineering software licenses are included with this Field PG?

It includes licenses for STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), and STEP 7 Micro/WIN V4.0.

Does the 6ES7716-2CA10-0EB4 support S5 systems?

No, this specific model is configured without an S5 interface and without an S5-EPROMMER.

What type of storage does the Field PG M4 use?

It is equipped with a 300 GB SATA Solid-State Drive (SSD) for fast and reliable data access.

What is the primary purpose of the SIMATIC Field PG M4?

It is designed as a robust, portable programming device for commissioning, diagnostics, and maintenance of Siemens SIMATIC automation systems in industrial environments.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...

How to Reverse a Three-Phase Motor Without Creating a New Fault

Reversing a three-phase motor is more than swapping two leads. This guide covers phase sequence, VFD settings, reversing contactors, encoder feedback, load checks, lockout, and commissioning tests.

Grounded or Floating 24 VDC? A Control-Panel Decision Guide

Grounding one side of a 24 VDC supply can improve fault detection and voltage reference, while floating circuits support isolation. This guide explains bonding, noise, first-fault behavior, and...

Seal-In Logic or OTL/OTU? Choosing PLC Memory Safely

Seal-in circuits and OTL/OTU instructions can hold the same command, but they fail differently. This guide compares scan behavior, restart risk, troubleshooting, permissives, and safer PLC design...