Siemens

Siemens 6ES7716-2CA16-0CB4 SIMATIC Field PG M4 Industrial Programming Device

SKU 6ES7716-2CA16-0CB4

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7716-2CA16-0CB4

  • Country of origin:Germany

  • Product Type: Industrial Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Dimensions: 39.5 x 30.0 x 17.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7716-2CA16-0CB4 is a SIMATIC Field PG M4 Premium Plus, a ruggedized industrial notebook engineered for automation programming, commissioning, and maintenance tasks in demanding plant environments. This model is equipped with a high-performance Intel Core i7-35X0M processor, 16 GB of RAM, and a fast 300 GB SATA solid-state drive (SSD) to handle complex engineering projects efficiently. It features a 15.6-inch Full HD display for clear visualization of schematics and HMI screens. The device comes pre-loaded with Windows 7 Ultimate SP1 and includes essential licenses for STEP 7 Professional, WinCC Advanced, and STEP 7 Micro/WIN, providing a comprehensive engineering platform out of the box. Please note, this configuration includes an AZERTY (French) keyboard layout.

Features

  • High-performance Intel Core i7-35X0M processor with Turbo Boost technology up to 3.6 GHz.
  • 16 GB of system memory (2x 8 GB modules) for multitasking with large automation projects.
  • Fast 300 GB Solid-State Drive (SATA) for rapid system boot and application loading.
  • High-resolution 15.6-inch Full HD (1920x1080) widescreen display.
  • Integrated DVD RW optical drive for software installation and data archiving.
  • Pre-licensed with STEP7 Professional combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), and STEP 7 Micro/WIN V4.0.
  • Includes an MPI cable for direct connection to SIMATIC S7 controllers.
  • Configured with an AZERTY (French) keyboard layout.

Applications

  • PLC programming, configuration, and diagnostics for SIMATIC controllers.
  • HMI and SCADA system development with WinCC.
  • On-site commissioning, system startup, and functional testing.
  • Mobile engineering workstation for plant maintenance and troubleshooting.
  • Process automation project management and data archiving.

Technical Specifications

General Information
Product SIMATIC Field PG M4 Premium Plus
Part Number 6ES7716-2CA16-0CB4
Manufacturer Siemens
Product Lifecycle Status Phase-Out
Hardware
Processor Intel Core i7-35X0M
Processor Cache 4 MB
Processor Speed 2.9 GHz (up to 3.6 GHz with Turbo Boost)
Graphics HD Graphic 4000
Memory (RAM) 16 GB (2x 8 GB)
Storage 300 GB Solid-State Drive (SATA)
Optical Drive DVD RW
Display Size 15.6 inch
Display Resolution Full HD (1920x1080)
Keyboard AZERTY (French)
Software & Licensing
Operating System Windows 7 Ultimate SP1, 64-bit
OS Languages German, English, French, Spanish, Italian
Included Licenses STEP7 Prof combo (V13/2010), WinCC Advanced combo (V13/WinCC flexible 2008), STEP 7 Micro/WIN V4.0
Software Version V13.0.1.0
Configuration Notes Does not include S5 interface or S5-EPROMMER. STEP 5 and STEP 7-Micro/WIN are not pre-installed. STEP 5 is not executable on Windows 7.
Logistics
Power Supply Cable Compatibility DE, FR, NL, SP, BEL, OES, SWD, FIN
Shipping Weight 3.50 kg
Package Dimensions (Calculated) 39.50 x 30.00 x 17.00 cm
Country of Origin Germany (Estimate)
Commodity Code 84713000
ECCN N

Installation Guidelines

CRITICAL WARNING: Always adhere to site-specific Lockout/Tagout (LOTO) procedures before connecting this device to any energized industrial equipment. Failure to de-energize machinery can result in severe injury or death. Ensure a stable and secure connection to the equipment's designated programming port.
  1. 1 Initial Setup: Unpack the Field PG and all accessories. Connect the appropriate power supply cable for your region to the AC adapter and charge the device fully before first use. Power on the device and complete the initial Windows 7 operating system setup.
  2. 2 Software Verification: Launch the installed Siemens automation software (e.g., TIA Portal) to verify that the included licenses are recognized and active. Install any additional software or project files required for your application.
  3. 3 Industrial Environment Use: Place the Field PG on a stable, level, and vibration-free surface. Ensure that the cooling fan vents are unobstructed to maintain proper operating temperature. Avoid exposure to excessive dust, moisture, or corrosive atmospheres.
  4. 4 Controller Connection: After confirming the target machine is in a safe, de-energized state, connect the provided MPI cable between the Field PG and the corresponding port on the SIMATIC controller. Establish communication within your engineering software to begin programming or diagnostic tasks.
  5. 5 Data Management: Implement a regular backup schedule for all automation projects stored on the Field PG. Create system restore points or full disk images to protect against data loss due to hardware failure or software corruption.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...