Siemens

Siemens 6ES7716-2DA13-0CA4 SIMATIC Field PG M4 Industrial Programming Device

SKU 6ES7716-2DA13-0CA4

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6ES7716-2DA13-0CA4

  • Country of origin:Germany

  • Product Type: Industrial Programming Device

  • Barcode: 84713000

  • Payment: T/T, Western Union

  • Weight: 3500g

  • Dimensions: 39.5 x 30.0 x 17.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6ES7716-2DA13-0CA4 is a SIMATIC Field PG M4 Premium Plus, a ruggedized industrial programming device designed for commissioning, servicing, and maintaining automation systems. This unit is equipped with an Intel Core i7-35X0M processor with a base clock speed of 2.9 GHz (up to 3.6 GHz with Turbo Boost), 16 GB of RAM (2x 8 GB), and a 480 GB SATA solid-state drive for fast performance in demanding industrial environments. It features a 15.6-inch Full HD display and runs on Windows 7 Ultimate SP1 (64-bit). This specific configuration is supplied without the legacy S5 interface or an S5-EPROMMER, and includes trial licenses for key SIMATIC engineering software.

Features

  • Processor: Intel Core i7-35X0M with 4 MB cache
  • Memory: 16 GB RAM (configured as 2x 8 GB modules)
  • Storage: 480 GB SATA Solid-State Drive (SSD)
  • Display: 15.6-inch Full HD with 1920x1080 resolution
  • Operating System: Windows 7 Ultimate SP1, 64-bit edition
  • Optical Drive: DVD RW drive
  • Keyboard: QWERTY layout (with German characters)
  • Power: Includes power supply cable for USA outlets
  • Software: Pre-loaded with trial licenses for STEP 7 Professional COMBO (V13/2010), WinCC Advanced COMBO (V13/WinCC flexible 2008), and STEP 7 Micro/WIN V4.0

Applications

  • PLC, HMI, and Drive system programming and configuration
  • On-site commissioning and startup of industrial machinery
  • Plant maintenance, diagnostics, and troubleshooting
  • Process monitoring and data archiving
  • Automation project development and simulation

Technical Specifications

Specification Value
Manufacturer Siemens
Product Series SIMATIC Field PG M4
Model Number 6ES7716-2DA13-0CA4
Product Type Premium Plus Industrial Programming Device
Processor Intel Core i7-35X0M
Processor Speed 2.9 GHz (up to 3.6 GHz with Turbo Boost)
Processor Cache 4 MB
Installed RAM 16 GB (2x 8 GB)
Storage 480 GB SATA Solid-State Drive (SSD)
Graphics Intel HD Graphics 4000
Display 15.6-inch Full HD (1920x1080)
Operating System Windows 7 Ultimate SP1, 64-bit (DE/EN/FR/ES/IT)
Product Lifecycle Status Phase-Out
Country of Origin Germany (Estimate)
Package Dimensions (Calculated) 39.5 x 30.0 x 17.0 cm
Shipping Weight 3.50 kg

Installation and Handling Guidelines

CRITICAL WARNING: This device is intended for use by trained automation professionals. Failure to follow safety procedures can result in equipment damage, data loss, or personal injury. Always de-energize connected control systems before making physical connections.
  1. 1 Upon receipt, carefully inspect the Field PG and its accessories for any signs of shipping damage. Do not power on the device if damage is suspected.
  2. 2 Use only the provided USA power supply cable and connect it to a properly grounded, stable AC power outlet. Avoid using ungrounded adapters or extension cords.
  3. 3 Power on the device and complete the initial Windows 7 operating system setup, including user account creation and network configuration.
  4. 4 Before connecting to any live industrial equipment, create a full system backup or restore point. This is critical for data integrity and system recovery.
  5. 5 Activate the included trial software licenses as needed for your engineering tasks. Note that these are evaluation licenses and will require purchase for continued use beyond the trial period.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop