Siemens

Siemens 6GK1561-3AA01 SIMATIC NET CP 5613 A2 Communications Processor

SKU 6GK1561-3AA01

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6GK1561-3AA01

  • Country of origin:Germany

  • Product Type: Communications Processors

  • Barcode: 85176200

  • Payment: T/T, Western Union

  • Weight: 600g

  • Dimensions: 12.7 x 5.1 x 17.8 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6GK1561-3AA01 is a CP 5613 A2 communications processor designed for legacy industrial automation systems. This module is implemented as a PCI card, providing a direct and reliable connection to PROFIBUS networks. It features a DP-RAM interface specifically for DP master operations and offers support for both PG and FDL protocols. This unit is intended for established applications running on operating systems up to Windows XP. The package includes the necessary DP-Base software, configuration tools, and runtime software on a CD-ROM. For systems requiring support for operating systems newer than Windows XP, the successor model 6GK1561-3AA02 is recommended.

Features

  • PCI card form factor for integration into industrial PCs.
  • Enables PROFIBUS network connectivity.
  • Functions as a PROFIBUS DP master.
  • Supports PG and FDL communication protocols.
  • Includes DP-Base software, configuration tool, and runtime software.
  • Single license for one installation.

Applications

  • Legacy manufacturing and production lines.
  • Process control systems requiring PROFIBUS DP master capabilities.
  • PC-based automation and control stations.
  • Data acquisition and monitoring systems on older platforms.

Technical Specifications

Specification Value
Manufacturer Siemens
Part Number 6GK1561-3AA01
Product Series SIMATIC NET
Product Type Communications Processor (CP 5613 A2)
Form Factor PCI Card
Network Connectivity PROFIBUS
Supported Protocols DP (Master), PG, FDL
Interface DP-RAM
Software Included DP-Base, Configuration Tool, Runtime Software
Supported Operating Systems Up to Windows XP (Legacy applications only)
Product Lifecycle Status Phase-Out
Shipping Weight 0.60 kg
Package Dimensions (Calculated) 12.70 x 5.10 x 17.80 cm
Commodity Code 85176200
ECCN EAR99
Country of Origin Germany (Calculated)

Installation Guidelines

CRITICAL WARNING: Electrical Hazard

Disconnect all power from the host computer and follow all Lockout/Tagout (LOTO) procedures before opening the chassis or handling the module. Failure to de-energize the system can result in severe electrical shock, equipment damage, and personal injury.

  1. 1 Ensure the host PC is fully de-energized and disconnected from its power source. Verify zero energy state.
  2. 2 Use a properly grounded electrostatic discharge (ESD) wrist strap and connect it to an unpainted metal surface of the computer chassis to prevent static damage to the card.
  3. 3 Open the computer chassis and select a vacant, compatible PCI slot. Remove the corresponding metal slot cover from the back of the chassis.
  4. 4 Carefully align the card's edge connector with the PCI slot and press down firmly and evenly until the card is fully seated.
  5. 5 Secure the card's metal mounting bracket to the chassis using the screw removed from the slot cover.
  6. 6 Connect the PROFIBUS network cable to the port on the card's bracket. Ensure the connector is securely fastened.
  7. 7 Replace the computer chassis cover, reconnect power, and proceed with software installation and configuration.

FAQ

What is the form factor of the 6GK1561-3AA01?

The 6GK1561-3AA01 is a standard PCI card designed for installation in an industrial or desktop computer.

Which industrial network is this card designed for?

This communications processor is designed for connection to PROFIBUS networks.

What is the primary function of this card on a PROFIBUS network?

It is designed to function as a PROFIBUS DP master, utilizing a DP-RAM interface for efficient data exchange.

Is this card suitable for modern operating systems like Windows 10 or 11?

No, this is a legacy product intended for older applications. It officially supports operating systems only up to Windows XP. For newer systems, Siemens recommends the successor model, 6GK1561-3AA02.

What software is included with the 6GK1561-3AA01?

The package includes DP-Base software, a configuration tool, and runtime software, all provided on a CD-ROM along with electronic manuals.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...