Siemens

Siemens 6GK5302-7GD00-3EA3 SCALANCE X302-7EEC Managed Industrial Ethernet Switch

SKU 6GK5302-7GD00-3EA3

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6GK5302-7GD00-3EA3

  • Country of origin:Germany

  • Product Type: Managed Industrial Ethernet Switch

  • Barcode: 85176200

  • Payment: T/T, Western Union

  • Weight: 2300g

  • Dimensions: 21.6 cm x 11.0 cm x 14.3 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Siemens 6GK5302-7GD00-3EA3 is a compact, managed Industrial Ethernet switch from the SCALANCE X302-7EEC series. This device is engineered for industrial networking applications, providing a versatile port configuration with 2x 10/100/1000 Mbit/s RJ45 ports for high-speed connections and 7x 100 Mbit/s LC fiber optic ports for long-distance or high-noise immunity links. It functions as a PROFINET IO device, enabling seamless integration into Siemens automation environments. The switch supports a wide-range 100-240V AC/DC power supply and includes an integrated redundancy manager to enhance network availability. A C-PLUG is included for straightforward device configuration backup and replacement.

Features

  • ■Managed Layer 2 switch with a compact, robust design for industrial use.
  • ■Integrated redundancy manager for high network availability.
  • ■Functions as a PROFINET IO device for direct automation system integration.
  • ■Supports standard office and IT protocols including RSTP, VLAN, and IGMP.
  • ■On-device diagnostics via integrated LEDs and an error signaling contact.
  • ■Includes a C-PLUG removable storage medium for configuration backup.

Applications

  • ■Factory automation and machine-level control networks.
  • ■Process control systems requiring redundant communication paths.
  • ■Connecting distributed I/O and control devices over long distances using fiber optics.
  • ■Integration into PROFINET-based automation architectures.

Technical Specifications

Specification Value
Manufacturer Siemens
Model Number 6GK5302-7GD00-3EA3
Product Series SCALANCE X302-7EEC
Product Type Managed Industrial Ethernet Switch
Power Supply 100-240 V AC/DC
RJ45 Ports 2x 10/100/1000 Mbit/s
Fiber Optic Ports 7x 100 Mbit/s LC
Management Features PROFINET IO Device, Network Management, RSTP, VLAN, IGMP
Redundancy Integrated Redundancy Manager
Product Lifecycle Status Phase-Out
Shipping Weight 2.30 kg
Package Dimensions (Calculated) 21.6 cm x 11.0 cm x 14.3 cm
Country of Origin Germany (Estimate)
Commodity Code 85176200
ECCN 5A002

Installation Guidelines

CRITICAL WARNING: HAZARD OF ELECTRIC SHOCK

Disconnect all power sources before installation or maintenance. This equipment is intended for use by qualified personnel only. Failure to de-energize the system can result in severe injury or death.

  1. 1 Ensure the control cabinet is de-energized and locked out according to safety procedures. Verify the absence of voltage.
  2. 2 Mount the switch securely onto a standard 35mm DIN rail within the enclosure, ensuring adequate clearance for ventilation and cable access.
  3. 3 Connect a protective earth (PE) conductor to the designated grounding terminal on the switch chassis. A low-impedance ground connection is essential for safety and noise immunity.
  4. 4 Terminate the 100-240V AC/DC power supply wiring to the correct terminals, observing polarity if applicable for DC sources.
  5. 5 Connect the RJ45 and LC fiber optic network cables. Ensure fiber optic connectors are clean before insertion and observe minimum bend radius requirements for all cables.
  6. 6 Insert the C-PLUG into its designated slot if using it for configuration storage.
  7. 7 After closing the cabinet and removing safety locks, re-energize the system. Verify the switch's status LEDs for correct power-up and network link activity.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.