Description
The Siemens 6GK5324-4QG10-1AR2 is a SCALANCE XR324-4M PoE, a managed Industrial Ethernet switch designed for 19-inch rack mounting. This device provides extensive connectivity with a total of 16 fixed RJ45 ports, eight of which support Power over Ethernet (PoE), and four slots for optional 2-port media modules for fiber optic or additional electrical connections. It operates as a PROFINET IO device and is powered by a 24 V DC supply. Diagnostics are facilitated through front-facing LEDs, a select/set pushbutton, and an error signaling contact for integration into plant monitoring systems.
Features
- Managed Layer 2 switching capabilities
- Standard 19-inch rack-mount form factor
- 8x 10/100/1000 Mbit/s RJ45 ports with Power over Ethernet (PoE)
- 8x 10/100/1000 Mbit/s standard RJ45 ports
- 4x slots for 2-port 10/100/1000 Mbit/s media modules (electrical or optical)
- Integrated PROFINET IO device functionality
- Front-panel LED diagnostics for status monitoring
- Error signaling contact for fault reporting
- Operates on a 24 V DC nominal power supply
Applications
- Machine-level networking in manufacturing
- Plant-wide network backbones
- Control cabinet installations in process automation
- Industrial data centers and server rooms
- Applications requiring PoE for devices like IP cameras or VOIP phones
Technical Specifications
| Specification |
Value |
| Product Type |
Managed Industrial Ethernet Switch |
| Manufacturer |
Siemens |
| Series |
SCALANCE |
| Model |
XR324-4M PoE |
| Part Number |
6GK5324-4QG10-1AR2 |
| Mounting |
19-inch Rack |
| Power Supply |
24 V DC |
| RJ45 Ports (with PoE) |
8x 10/100/1000 Mbit/s |
| RJ45 Ports (without PoE) |
8x 10/100/1000 Mbit/s |
| Media Module Slots |
4 (for 2-port 10/100/1000 Mbit/s modules) |
| Industrial Protocol |
PROFINET IO Device |
| Product Lifecycle Status |
Phase-Out |
| Shipping Weight |
5.00 kg |
| Package Dimensions (Calculated) |
44.9 cm x 30.5 cm x 4.36 cm |
| Country of Origin |
Germany (Estimated) |
| Commodity Code |
85389091 |
| ECCN |
5A002 |
Installation Guidelines
CRITICAL WARNING: Hazardous voltages may be present. Installation must be performed by qualified personnel only. Failure to de-energize equipment before installation can result in severe injury or death. Always follow local Lockout/Tagout (LOTO) procedures.
-
1
Ensure the control cabinet or rack is fully de-energized and locked out before beginning work. Verify the absence of voltage.
-
2
Securely mount the SCALANCE switch into the 19-inch rack using the appropriate mounting hardware. Ensure adequate ventilation space around the unit.
-
3
Connect a low-impedance protective earth (PE) conductor to the designated grounding terminal on the switch chassis. This is critical for safety and noise immunity.
-
4
Connect the 24 V DC power supply wiring to the power input terminals, observing correct polarity. Use appropriately sized conductors for the load.
-
5
Connect network devices using shielded Ethernet cables. Connect the error signaling contact wiring if required by the application.
-
6
After all connections are secure, remove LOTO devices and re-energize the cabinet. Verify the switch powers on and that status LEDs indicate normal operation.