Siemens

Siemens 6GT2001-0EA10 MOBY I SLG 40 Read/Write Device

SKU 6GT2001-0EA10

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens

  • Product No.: 6GT2001-0EA10

  • Country of origin:Germany

  • Product Type: Read/writing devices

  • Barcode: 84719000

  • Payment: T/T, Western Union

  • Weight: 400g

  • Dimensions: 7.60cm x 5.10cm x 68.60cm

  • Shipping port: Xiamen

  • Warranty: 12 months

The 6GT2001-0EA10 is a MOBY I SLG 40 Read/Write Device designed for high-performance industrial RFID identification tasks. This unit features a detached M30 x 57 antenna, providing flexibility for integration in confined mounting spaces. The 6GT2001-0EA10 offers an IP65 degree of protection, ensuring durability in harsh industrial environments, and operates effectively across a wide temperature range of -25 degC to +70 degC. With a maximum limit distance of 70 mm (depending on the specific MDS transponder used), this device is optimized for reliable data exchange in automated tracking and logistics applications.

Features

  • SLG 40 model with a compact, detached M30 x 57 antenna for versatile installation.
  • Robust IP65-rated housing suitable for demanding industrial conditions.
  • Operates in an ambient temperature range from -25 degC to +70 degC.
  • High-reliability data communication for MOBY I RFID systems.
  • Max limit distance of 70 mm (varies by MDS transponder type).

Applications

  • Automated assembly lines and manufacturing tracking.
  • Warehouse management and logistics identification.
  • Material flow control in production environments.
  • Tool and workpiece identification in machining centers.

Technical Specifications

Parameter Specification
Manufacturer Siemens
Brand MOBY
Range I
Product Type Read/Write Device
Model SLG 40
Antenna Detached M30 x 57
Degree of Protection IP65
Temperature Range -25 degC to +70 degC
Max. Limit Distance 70 mm (transponder dependent)
Dimensions 12.50 cm x 4.00 cm x 7.50 cm (Device)
Weight 0.40 kg
Commodity Code 84719000

Installation Guidelines

  • Mounting: Ensure the detached antenna is securely mounted using the provided M30 threading. Avoid installation in close proximity to large metal surfaces if possible to prevent signal attenuation.
  • Environmental Exposure: While the unit is IP65 rated, ensure cable connections are sealed and protected from direct chemical washdowns or extreme moisture.
  • Signal Interference: Keep the read/write field clear of metallic objects and other high-frequency noise sources to maintain the maximum 70 mm operating distance.
  • Wiring: Use appropriate interface cabling to connect the SLG 40 to the respective RFID controller, ensuring correct shielding to minimize EMI.

FAQ

What is the maximum read distance of the 6GT2001-0EA10?

The maximum limit distance is 70 mm, though this value depends on the specific MDS transponder used.

Does this device include the antenna?

Yes, it is supplied with a detached M30 x 57 antenna.

What is the IP rating for this RFID reader?

The device features an IP65 degree of protection, making it suitable for industrial environments.

What is the operating temperature range for this module?

The module is designed to operate in temperatures ranging from -25 degC to +70 degC.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
Germany
Power source
DC Power

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...